Electrochemiluminescence immunosensor for tropomyosin using carbon nanohorns/Nafion/Fe3O4@Pd screen-printed electrodes.
Noor Azam, Nura Fazira; Mohd-Naim, Noor Faizah; Kurup, Chitra Padmakumari; Ahmed, Minhaz Uddin.
Afiliação
  • Noor Azam NF; Biosensors and Nanobiotechnology Laboratory, Chemical Science Programme, Faculty of Science, Universiti Brunei Darussalam, Jalan Tungku Link, Gadong, BE, 1410, Brunei Darussalam.
  • Mohd-Naim NF; PAPRSB Institute of Health Sciences, Universiti Brunei Darussalam, Jalan Tungku Link, Gadong, BE, 1410, Brunei Darussalam.
  • Kurup CP; Biosensors and Nanobiotechnology Laboratory, Chemical Science Programme, Faculty of Science, Universiti Brunei Darussalam, Jalan Tungku Link, Gadong, BE, 1410, Brunei Darussalam.
  • Ahmed MU; Biosensors and Nanobiotechnology Laboratory, Chemical Science Programme, Faculty of Science, Universiti Brunei Darussalam, Jalan Tungku Link, Gadong, BE, 1410, Brunei Darussalam. minhaz.ahmed@ubd.edu.bn.
Mikrochim Acta ; 187(8): 456, 2020 07 18.
Article em En | MEDLINE | ID: mdl-32683494
This study focuses on developing a highly sensitive immunosensor by immobilizing oxidized carbon nanohorns/Nafion/Fe3O4@Pd nanocomposite on carbon screen-printed electrodes (SPEs) for the detection of tropomyosin (Tro-Ag). The performance of the fabricated immunosensor was investigated via electrochemiluminescence (ECL) method, resulting from the chemical reaction between tris(bipyridine)ruthenium(II) chloride ([Ru(bpy)3]Cl2) and tripropylamine (TPrA), and the peak intensity is recorded at 1.0 V. The nanocomposite is able to enhance the ECL intensity of [Ru(bpy)3]2 +/TPrA system and achieves high sensitivity of 28.16 fg/mL with a dynamic working range of 28.16 fg/mL to 100 ng/ml.. Furthermore, the immunosensor demonstrated a decent stability and good repeatability for Tro-Ag detection in food products. Graphical abstract The schematic representation of the modified carbon SPE with CNHs-OH/Nafion/Fe3O4@Pd and the signal produced in the (a) absence and (b) presence of Tro-Ag.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Tropomiosina / Imunoensaio / Nanocompostos / Técnicas Eletroquímicas / Medições Luminescentes Limite: Animals Idioma: En Revista: Mikrochim Acta Ano de publicação: 2020 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Tropomiosina / Imunoensaio / Nanocompostos / Técnicas Eletroquímicas / Medições Luminescentes Limite: Animals Idioma: En Revista: Mikrochim Acta Ano de publicação: 2020 Tipo de documento: Article