Your browser doesn't support javascript.
loading
Smart Bimodal Imaging of Hypochlorous Acid In Vivo Using a Heterobimetallic Ruthenium(II)-Gadolinium(III) Complex Probe.
Shi, Wenbo; Song, Bo; Liu, Zhiwei; Zhang, Wenzhu; Tan, Mingqian; Song, Fengling; Yuan, Jingli.
Afiliação
  • Shi W; State Key Laboratory of Fine Chemicals, School of Chemical Engineering, Dalian University of Technology, Dalian 116024, P. R. China.
  • Song B; State Key Laboratory of Fine Chemicals, School of Chemical Engineering, Dalian University of Technology, Dalian 116024, P. R. China.
  • Liu Z; State Key Laboratory of Fine Chemicals, School of Chemical Engineering, Dalian University of Technology, Dalian 116024, P. R. China.
  • Zhang W; State Key Laboratory of Fine Chemicals, School of Chemical Engineering, Dalian University of Technology, Dalian 116024, P. R. China.
  • Tan M; School of Food Science and Technology, National Engineering Research Center of Seafood, Dalian Polytechnic University, Qinggongyuan1, Ganjingzi District, Dalian 116034, P. R. China.
  • Song F; State Key Laboratory of Fine Chemicals, School of Chemical Engineering, Dalian University of Technology, Dalian 116024, P. R. China.
  • Yuan J; State Key Laboratory of Fine Chemicals, School of Chemical Engineering, Dalian University of Technology, Dalian 116024, P. R. China.
Anal Chem ; 92(16): 11145-11154, 2020 08 18.
Article em En | MEDLINE | ID: mdl-32702968
ABSTRACT
A unique heterobimetallic Ru(II)-Gd(III) complex, Ru-AN-Gd, is reported to serve as an effective probe for bimodal phosphorescence-magnetic resonance (MR) imaging of hypochlorous acid (HClO) in vitro and in vivo. The probe was designed by incorporating a MR contrast agent, Gd-DOTA, into a HClO-responsive bipyridine-Ru(II) complex derivative. The specific reaction between Ru-AN-Gd and HClO triggers the cleavage of an ether bond in the probe molecule, resulting in phosphorescence turn-on and MR turn-off responses to HClO. The integration of MR and phosphorescence detection modes allows the probe to be employed for detecting HClO in a quite wide concentration range (0.6-2000 µM) and for imaging HClO at various resolutions ranging from the subcellular level to the whole body without a depth limit. Its applicability was demonstrated by phosphorescence imaging of lysosomal HClO in live cells, visualization of HClO generation in a mouse arthritis model, and bimodal phosphorescence-MR imaging of HClO in drug-induced acute liver and kidney injury of a mouse. The research achievements suggested the potential of Ru-AN-Gd for diagnosis and treatment monitoring of HClO-related disease.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Ácido Hipocloroso / Meios de Contraste / Substâncias Luminescentes / Complexos de Coordenação Limite: Animals / Humans Idioma: En Revista: Anal Chem Ano de publicação: 2020 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Ácido Hipocloroso / Meios de Contraste / Substâncias Luminescentes / Complexos de Coordenação Limite: Animals / Humans Idioma: En Revista: Anal Chem Ano de publicação: 2020 Tipo de documento: Article