Your browser doesn't support javascript.
loading
Complex Method of CT and Morphological Examination of Placental Angioarchitechtonics.
Shchegolev, A I; Tumanova, U N; Lyapin, V M; Kozlova, A V; Bychenko, V G; Sukhikh, G T.
Afiliação
  • Shchegolev AI; V. I. Kulakov National Medical Research Center of Obstetrics, Gynecology, and Perinatology, Ministry of Health of Russian Federation, Moscow, Russia. patan777@gmail.com.
  • Tumanova UN; V. I. Kulakov National Medical Research Center of Obstetrics, Gynecology, and Perinatology, Ministry of Health of Russian Federation, Moscow, Russia.
  • Lyapin VM; V. I. Kulakov National Medical Research Center of Obstetrics, Gynecology, and Perinatology, Ministry of Health of Russian Federation, Moscow, Russia.
  • Kozlova AV; V. I. Kulakov National Medical Research Center of Obstetrics, Gynecology, and Perinatology, Ministry of Health of Russian Federation, Moscow, Russia.
  • Bychenko VG; V. I. Kulakov National Medical Research Center of Obstetrics, Gynecology, and Perinatology, Ministry of Health of Russian Federation, Moscow, Russia.
  • Sukhikh GT; V. I. Kulakov National Medical Research Center of Obstetrics, Gynecology, and Perinatology, Ministry of Health of Russian Federation, Moscow, Russia.
Bull Exp Biol Med ; 169(3): 405-411, 2020 Jul.
Article em En | MEDLINE | ID: mdl-32748143
ABSTRACT
We propose an original method of complex assessment of the placental angioarchitechtonics based on computed tomography (CT) and morphological examination. A prerequisite condition of successful examination and assessment of the placental angioarchitechtonics is the pre-preparative stage including clearing of the placental and umbilical cord vessels from blood clots by placement of placenta into 10% hypertonic NaCl solution and then on a hygroscopic substrate. The major stage of this method is injection of contrast staining mixtures into the umbilical vessels followed by CT. The concentration of radiocontrast agent in water solution of gouache should be 70% for arteries and 15% for veins. The volumes of mixtures for contrast staining should be calculated according to the weight of the placenta. The contrast staining mixture was first injected into the catheterized unpaired umbilical vein, and then into both umbilical arteries. Each injection of the contrast staining mixture was visually inspected; then branching of the stained vessel was photographed and scanned by CT. The CT scans were used to construct 3D models of placental vessels and spectral color maps, which made it possible to examine the peculiarities of placental angioarchitechtonics, to identify and evaluate anastomoses of placental vessels, and to establish the type of these anastomoses.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Placenta / Tomografia Computadorizada por Raios X Limite: Female / Humans / Pregnancy Idioma: En Revista: Bull Exp Biol Med Ano de publicação: 2020 Tipo de documento: Article País de afiliação: Federação Russa

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Placenta / Tomografia Computadorizada por Raios X Limite: Female / Humans / Pregnancy Idioma: En Revista: Bull Exp Biol Med Ano de publicação: 2020 Tipo de documento: Article País de afiliação: Federação Russa