Your browser doesn't support javascript.
loading
The effect of intravitreal dexamethasone implant on central foveal thickness and choroidal thickness in retinal vein occlusion.
Erogul, O; Yozgat, Z; Sabaner, M C; Dogan, M; Gobeka, H H.
Afiliação
  • Erogul O; Department of Ophthalmology, Faculty of Medicine, Afyonkarahisar University of Health Sciences, Afyonkarahisar, Turkey.
  • Yozgat Z; Department of Ophthalmology, Faculty of Medicine, Afyonkarahisar University of Health Sciences, Afyonkarahisar, Turkey.
  • Sabaner MC; Department of Ophthalmology, Faculty of Medicine, Afyonkarahisar University of Health Sciences, Afyonkarahisar, Turkey.
  • Dogan M; Department of Ophthalmology, Faculty of Medicine, Afyonkarahisar University of Health Sciences, Afyonkarahisar, Turkey.
  • Gobeka HH; Department of Ophthalmology, Afyonkarahisar State Hospital, Afyonkarahisar, Afyonkarahisar, Turkey.
Niger J Clin Pract ; 24(1): 121-126, 2021 Jan.
Article em En | MEDLINE | ID: mdl-33473037
ABSTRACT

AIM:

To investigate the effect of intravitreal dexamethasone implant on central foveal thickness and choroidal thickness in retinal vein occlusion. MATERIALS AND

METHODS:

Clinical records and optical coherence tomography (OCT) scans of 41 naïve patients with retinal vein occlusion (RVO), who were initially treated with intravitreal dexamethasone (DEX) implant between 2016 and 2017 at Kocatepe University Faculty of Medicine, Department of Ophthalmology were investigated. Collected data included age and sex of the patients, crystalline lens status, baseline and final intraocular pressure, and OCT parameters including central foveal thickness and choroidal thickness.

RESULTS:

Twenty-two (53.7%) female and 19 (46.3%) male patients were enrolled in the study. There were 30 phakic and 11 pseudophakic patients. The intraocular pressure increased significantly from 15.19 mmHg to 17.8 mmHg (P = 0.005), and cataract extraction was performed in two patients who developed cataract after the treatment. There was a significant decrease in the central foveal thickness from 556 µm to 288 µm (P < 0.001). In addition, although there was no statistically significant change in choroidal thickness in the patients with branched retinal vein occlusion (P = 0.423), the patients with central retinal vein occlusion had statistically significant decrease in choroidal thickness measurements (P = 0.049).

CONCLUSION:

Therapeutic effect of the DEX implant not only influences retinal layer. Its influence may also extend further to the choroid layer, thereby leading to decrease in the choroidal thickness. Our results were mostly similar to the results of studies in literature which investigated the effects of the DEX implant therapy on the choroidal thickness of the patients with RVO.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Oclusão da Veia Retiniana / Edema Macular Limite: Female / Humans / Male Idioma: En Revista: Niger J Clin Pract Assunto da revista: MEDICINA Ano de publicação: 2021 Tipo de documento: Article País de afiliação: Turquia

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Oclusão da Veia Retiniana / Edema Macular Limite: Female / Humans / Male Idioma: En Revista: Niger J Clin Pract Assunto da revista: MEDICINA Ano de publicação: 2021 Tipo de documento: Article País de afiliação: Turquia