Zirconia-Toughened Alumina Coated Ti6Al4V via Additive Manufacturing.
Mater Lett
; 2912021 May 15.
Article
em En
| MEDLINE
| ID: mdl-33692601
CoCr alloy-based femoral heads have failed prematurely due to galvanic-induced corrosion when coupled with a titanium hip stem. Coupling a titanium based-femoral head with the titanium hip stem is ideal in addressing this failure mode. Ti6Al4V (Ti64) alloy was reinforced with zirconia-toughened alumina (ZTA) by directed-energy deposition (DED)-based additive manufacturing (AM) to address that concern. Preliminary materials processing work resulted in failed samples due to cracking, porosity, and delamination. After careful parameter optimization, a Ti64+5wt.%ZTA (5ZTA) composition produced a metallurgically sound and coherent interface, minimal porosity, and bulk structures. Hardness was observed to increase by 27%, normalized wear rate reduced by 25%, and contact resistance increased during in vitro tribological testing along with faster surface re-passivation.