Your browser doesn't support javascript.
loading
Microfluidic thread-based electrochemical aptasensor for rapid detection of Vibrio parahaemolyticus.
Jiang, Hai; Sun, Zhikang; Guo, Qian; Weng, Xuan.
Afiliação
  • Jiang H; School of Mechanical and Electrical Engineering, University of Electronic Science and Technology of China, Chengdu, Sichuan, 611731, China.
  • Sun Z; School of Mechanical and Electrical Engineering, University of Electronic Science and Technology of China, Chengdu, Sichuan, 611731, China.
  • Guo Q; School of Mechanical and Electrical Engineering, University of Electronic Science and Technology of China, Chengdu, Sichuan, 611731, China.
  • Weng X; School of Mechanical and Electrical Engineering, University of Electronic Science and Technology of China, Chengdu, Sichuan, 611731, China. Electronic address: xuanweng@uestc.edu.cn.
Biosens Bioelectron ; 182: 113191, 2021 Jun 15.
Article em En | MEDLINE | ID: mdl-33780852
ABSTRACT
Vibrio parahaemolyticus is one of the foodborne bacteria that widely present in seafood as well as the leading cause of seafood-associated bacterial gastroenteritis. Traditional identification of such pathogens mainly relies on culturing methods, ELISA or PCR. These methods are usually laborious, time-consuming with poor diagnosis competences, or require costly and bulky equipment though of high sensitivity. In this study, a thread-based microfluidic electrochemical aptasensor was designed, fabricated and tested by using label-free aptamer immunosensing technology for rapid and highly sensitive detection of Vibrio parahaemolyticus in seafood. Both the microfluidic channels and electrodes were simply fabricated on threads. Molybdenum disulfide (MoS2) nanosheets were used to obtain enhanced sensitivity of the electrochemical measurement. When used in detecting Vibrio parahaemolyticus, the proposed aptasensor has a dynamic detection range of 10-106 CFU mL-1 with a detection limit of 5.74 CFU mL-1. Compared with traditional plate counting method, the proposed aptasensor has higher detection sensitivity and less assay time (30 min), while high specificity and accuracy are kept. The proposed microfluidic thread-based electrochemical aptasensor grabs the potential to detect other pathogens by simply functionalizing the threaded electrodes with aptamers for targeted biological substances.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Vibrio parahaemolyticus / Técnicas Biossensoriais Tipo de estudo: Diagnostic_studies Idioma: En Revista: Biosens Bioelectron Assunto da revista: BIOTECNOLOGIA Ano de publicação: 2021 Tipo de documento: Article País de afiliação: China

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Vibrio parahaemolyticus / Técnicas Biossensoriais Tipo de estudo: Diagnostic_studies Idioma: En Revista: Biosens Bioelectron Assunto da revista: BIOTECNOLOGIA Ano de publicação: 2021 Tipo de documento: Article País de afiliação: China