Your browser doesn't support javascript.
loading
[The effect of different diagnostic standards on the diagnosis of suspected occupational noise-induced deafness].
Xue, L J; Tang, J B; Wang, J X; Yang, A C; Li, Z Y.
Afiliação
  • Xue LJ; Qingyuan City Hospital for Occupational Disease Prevention and Treatment, Qingyuan 511500, China.
  • Tang JB; Qingyuan City Hospital for Occupational Disease Prevention and Treatment, Qingyuan 511500, China.
  • Wang JX; Occupational Safety Research Center of National Health Commission, Beijing 100036, China.
  • Yang AC; Guangdong Province Hospital for Occupational Disease Prevention and Treatment, Guang zhou 510300, China.
  • Li ZY; Qingcheng Center for Disease Control and Prevention of Qingxin City, Qingxin 511500, China.
Article em Zh | MEDLINE | ID: mdl-33781038
ABSTRACT

Objective:

To explore the effect of different diagnostic criteria on occupational noise-induced deafness (Onid) , and to provide theoretical basis for the revision of ONID diagnostic criteria.

Methods:

From January 2016 to January 2018, the physical examination results of noise-exposed workers during occupational health examination in Qingyuan Occupational Disease Prevention and Treatment Hospital were retrospectively investigated in September 2019, with Gbz 49-2014《diagnosis of occupational noise deafness》as the study object, 471 workers suspected of Onid were weighted with different combinations of high frequency hearing threshold, and the better ear weight was calculated, compared with the diagnostic criteria of 2007 and 2014, the degree of hearing loss was evaluated. SPSS 22.0 was used for statistical analysis, χ(2) test was used for counting data, and non-parametric test was used for measuring bias data.

Results:

The average age of 471 subjects was (40.32±7.01) years, and the average age of exposure to noise was (7.11±3.44) years. On the basis of the 2007 edition diagnostic standard, the suspected ONID diagnostic rate of different high frequency auditory threshold was increased by 16.35% and 30.15% at 3.0 kHz, 6.0 kHz increased by 20.17%, 3.0 kHz+4.0 kHz increased by 22.29%, 3.0 kHz+6.0 kHz increased by 17.20%, 4.0 kHz+6.0 kHz increased by 25.27%, the differences were statistically significant (P<0.05) , the frequency of 3.0 kHz+4.0 kHz+6.0 kHz increased by 22.29%. Using the 2014 edition diagnostic standard, the diagnostic rate of Onid was reduced by 30.15% and 13.80%, 6 kHz is 9.98% lower, 3.0 kHz+4.0 kHz is 7.86% lower, 3.0 kHz+6.0 kHz is 12.95% lower, 4.0 kHz+6.0 is 4.88% lower, the high frequency of 3.0 kHz+4.0 kHz+6.0 kHz decreased by 7.86%, the differences were statistically significant (P<0.05) .

Conclusion:

The diagnosis rate of suspected Onid is increased by weighting different high frequency hearing threshold, in which the weighted 4kHz high frequency has the greatest influence on the result, and the weighted 3 kHz high frequency has the least.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Exposição Ocupacional / Surdez / Perda Auditiva Provocada por Ruído / Ruído Ocupacional / Doenças Profissionais Tipo de estudo: Diagnostic_studies / Etiology_studies / Guideline / Observational_studies Limite: Child / Child, preschool / Humans Idioma: Zh Revista: Zhonghua Lao Dong Wei Sheng Zhi Ye Bing Za Zhi Assunto da revista: MEDICINA OCUPACIONAL Ano de publicação: 2021 Tipo de documento: Article País de afiliação: China

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Exposição Ocupacional / Surdez / Perda Auditiva Provocada por Ruído / Ruído Ocupacional / Doenças Profissionais Tipo de estudo: Diagnostic_studies / Etiology_studies / Guideline / Observational_studies Limite: Child / Child, preschool / Humans Idioma: Zh Revista: Zhonghua Lao Dong Wei Sheng Zhi Ye Bing Za Zhi Assunto da revista: MEDICINA OCUPACIONAL Ano de publicação: 2021 Tipo de documento: Article País de afiliação: China