Your browser doesn't support javascript.
loading
Comparison of two methods for aerobic threshold determination.
Aunola, S; Rusko, H.
Afiliação
  • Aunola S; Rehabilitation Research Centre of the Social Insurance Institution, Turku, Finland.
Article em En | MEDLINE | ID: mdl-3396556
ABSTRACT
A new method of aerobic threshold (AerT) determination, as a minimum of so-called lactate equivalent (Berg et al. 1980; Lehmann et al. 1983), was compared with the generally used method (AerT1) presented first by Wasserman et al. (1973). The comparison was made with data from 32 subjects in repeated maximal exercise tests on a bicycle ergometer. The AerT as a minimum of lactate equivalent was determined using both a computerized method for curve fitting (AerT3) and visual inspection (AerT2). AerT2 and AerT3 showed similarity the regression coefficient was 0.88 and 0.95 and the correlation coefficient was 0.84 and 0.88 in the first and in the second tests, respectively. AerT1 and AerT2 showed similar mean estimated values, but AerT3 showed slightly higher mean values than AerT1 (p less than 0.05 and p less than 0.01) or AerT2 (p less than 0.01). The regression coefficients between AerT1 and AerT2 or AerT3 (0.60-0.71) showed different slopes from the identity (p less than 0.001). The corresponding correlation coefficients were 0.88 and 0.89 with AerT2, and 0.75 and 0.79 with AerT3 respectively in the first and second tests. However, in two thirds of all determinations the difference between these two estimation methods (AerT1 and AerT2) was less than or equal to 0.10 l O2.min-1. In conclusion, AerT as a minimum of lactate equivalent differed slightly from AerT determined using the traditional method. However, its determination criterion is unambiguous and allows objective computerized curve fitting. The physiological correlates of this new AerT index should be studied carefully before final evaluation of its usefulness in applications can be made.
Assuntos
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Fisiologia Limite: Adult / Humans / Male / Middle aged Idioma: En Revista: Eur J Appl Physiol Occup Physiol Ano de publicação: 1988 Tipo de documento: Article País de afiliação: Finlândia
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Fisiologia Limite: Adult / Humans / Male / Middle aged Idioma: En Revista: Eur J Appl Physiol Occup Physiol Ano de publicação: 1988 Tipo de documento: Article País de afiliação: Finlândia