Your browser doesn't support javascript.
loading
Development of low-cost planar electrodes and microfluidic channels for applications in capacitively coupled contactless conductivity detection (C4 D).
Takekawa, Victor Sadanory; Marques, Letícia Aparecida; Strubinger, Ethan; Segato, Thiago Pinotti; Bogusz, Stanislau; Brazaca, Laís Canniatti; Carrilho, Emanuel.
Afiliação
  • Takekawa VS; Instituto de Química de São Carlos, Universidade de São Paulo, São Carlos, São Paulo, Brazil.
  • Marques LA; Instituto Nacional de Ciência e Tecnologia de Bioanalítica-INCTBio, Campinas, São Paulo, Brazil.
  • Strubinger E; Instituto de Química de São Carlos, Universidade de São Paulo, São Carlos, São Paulo, Brazil.
  • Segato TP; Instituto Nacional de Ciência e Tecnologia de Bioanalítica-INCTBio, Campinas, São Paulo, Brazil.
  • Bogusz S; Instituto de Química de São Carlos, Universidade de São Paulo, São Carlos, São Paulo, Brazil.
  • Brazaca LC; Instituto Nacional de Ciência e Tecnologia de Bioanalítica-INCTBio, Campinas, São Paulo, Brazil.
  • Carrilho E; Department of Chemical and Biomolecular Engineering, North Carolina State University, Raleigh, NC.
Electrophoresis ; 42(16): 1560-1569, 2021 08.
Article em En | MEDLINE | ID: mdl-34080201
ABSTRACT
Electrochemical techniques are commonly applied to micro total analysis system (µTAS) devices mainly due to its high sensitivity and miniaturization capacity. Among many electrochemical techniques, capacitively coupled contactless conductivity detection (C4 D) stands out for not requiring direct electrode-solution contact, avoiding several problems such as electrolysis, bubble formation, and metal degradation. Furthermore, the instrumentation required for C4 D measurements is compact, low cost, and easy to use, allowing in situ measurements to be performed even by nonspecialized personal. Contrarily, the production of metallic electrodes and microchannels adequate for C4 D measurements commonly requires specialized facilities and workers, increasing the costs of applying these methods. We propose alternatives to batch manufacture metallic electrodes and polymeric microchannels for C4 D analysis using more straightforward equipment and lower-cost materials. Three devices with different dielectric layer compositions and electrode sizes were tested and compared regarding their analytical performance. The constructed platforms have shown a reduction of more than 64% in cost when compared to traditional techniques and displayed good linearity (R2 ≥ 0.994), reproducibility (RSD ≤ 4.07%, n = 3), and limits of detection (≤0.26 mmol/L) when measuring standard NaCl samples. Therefore, the proposed methods were successfully validated and are available for further C4 D applications such as diagnosis of dry-eye syndrome.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Microfluídica / Eletrodos Tipo de estudo: Diagnostic_studies / Health_economic_evaluation Limite: Humans Idioma: En Revista: Electrophoresis Ano de publicação: 2021 Tipo de documento: Article País de afiliação: Brasil

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Microfluídica / Eletrodos Tipo de estudo: Diagnostic_studies / Health_economic_evaluation Limite: Humans Idioma: En Revista: Electrophoresis Ano de publicação: 2021 Tipo de documento: Article País de afiliação: Brasil