Your browser doesn't support javascript.
loading
Development and validation of low-intensity pulsed ultrasound systems for highly controlled in vitro cell stimulation.
Fontana, F; Iberite, F; Cafarelli, A; Aliperta, A; Baldi, G; Gabusi, E; Dolzani, P; Cristino, S; Lisignoli, G; Pratellesi, T; Dumont, E; Ricotti, L.
Afiliação
  • Fontana F; The BioRobotics Institute, Scuola Superiore Sant'Anna, 56127 Pisa, Italy; Department of Excellence in Robotics & AI, Scuola Superiore Sant'Anna, 56127 Pisa, Italy. Electronic address: fr.fontana@santannapisa.it.
  • Iberite F; The BioRobotics Institute, Scuola Superiore Sant'Anna, 56127 Pisa, Italy; Department of Excellence in Robotics & AI, Scuola Superiore Sant'Anna, 56127 Pisa, Italy. Electronic address: federica.iberite@santannapisa.it.
  • Cafarelli A; The BioRobotics Institute, Scuola Superiore Sant'Anna, 56127 Pisa, Italy; Department of Excellence in Robotics & AI, Scuola Superiore Sant'Anna, 56127 Pisa, Italy. Electronic address: andrea.cafarelli@santannapisa.it.
  • Aliperta A; The BioRobotics Institute, Scuola Superiore Sant'Anna, 56127 Pisa, Italy; Department of Excellence in Robotics & AI, Scuola Superiore Sant'Anna, 56127 Pisa, Italy. Electronic address: andrea.aliperta@santannapisa.it.
  • Baldi G; The BioRobotics Institute, Scuola Superiore Sant'Anna, 56127 Pisa, Italy; Department of Excellence in Robotics & AI, Scuola Superiore Sant'Anna, 56127 Pisa, Italy. Electronic address: gabriele.baldi@santannapisa.it.
  • Gabusi E; IRCCS Istituto Ortopedico Rizzoli, SC Laboratorio di Immunoreumatologia e Rigenerazione Tissutale, 40136 Bologna, Italy. Electronic address: elena.gabusi@ior.it.
  • Dolzani P; IRCCS Istituto Ortopedico Rizzoli, SC Laboratorio di Immunoreumatologia e Rigenerazione Tissutale, 40136 Bologna, Italy. Electronic address: paolo.dolzani@ior.it.
  • Cristino S; Dipartimento Scienze Biologiche, Geologiche e Ambientali (BiGeA), Università di Bologna, 40126 Bologna, Italy. Electronic address: sandra.cristino@unibo.it.
  • Lisignoli G; IRCCS Istituto Ortopedico Rizzoli, SC Laboratorio di Immunoreumatologia e Rigenerazione Tissutale, 40136 Bologna, Italy. Electronic address: gina.lisignoli@ior.it.
  • Pratellesi T; BAC Technology s.r.l., 50063 Florence, Italy. Electronic address: tiziano.pratellesi@gmail.com.
  • Dumont E; Image Guided Therapy, 33600 Pessac, France. Electronic address: erik.dumont@imageguidedtherapy.com.
  • Ricotti L; The BioRobotics Institute, Scuola Superiore Sant'Anna, 56127 Pisa, Italy; Department of Excellence in Robotics & AI, Scuola Superiore Sant'Anna, 56127 Pisa, Italy. Electronic address: leonardo.ricotti@santannapisa.it.
Ultrasonics ; 116: 106495, 2021 Jun 15.
Article em En | MEDLINE | ID: mdl-34186322
ABSTRACT
This work aims to describe the development and validation of two low-intensity pulsed ultrasound stimulation systems able to control the dose delivered to the biological target. Transducer characterization was performed in terms of pressure field shape and intensity, for a high-frequency range (500 kHz to 5 MHz) and for a low-frequency value (38 kHz). This allowed defining the distance, on the beam axis, at which biological samples should be placed during stimulation and to exactly know the intensity at the target. Carefully designed retaining systems were developed, for hosting biological samples. Sealing tests proved their impermeability to external contaminants. The assembly/de-assembly time of the systems resulted ~3 min. Time-domain acoustic simulations allowed to precisely estimate the ultrasound beam within the biological sample chamber, thus enabling the possibility to precisely control the pressure to be transmitted to the biological target, by modulating the transducer's input voltage. Biological in vitro tests were also carried out, demonstrating the sterility of the system and the absence of toxic and inflammatory effects on growing cells after multiple immersions in water, over seven days.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: Ultrasonics Ano de publicação: 2021 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: Ultrasonics Ano de publicação: 2021 Tipo de documento: Article