[Study on the Analytical Method of Solid Phase Extraction-Ultra Performance Liquid Chromatography Tandem Quadrupole Linear Ion Trap Mass Spectrometry for 12 Perfluorinated Compounds in Human Urine].
Sichuan Da Xue Xue Bao Yi Xue Ban
; 52(4): 679-685, 2021 Jul.
Article
em Zh
| MEDLINE
| ID: mdl-34323049
ABSTRACT
OBJECTIVE:
To establish a method for simultaneous determination of 12 kinds of perfluorinated compounds (PFCs) in human urine based on ultra performance liquid chromatography tandem quadrupole linear ion trap mass spectrometry (UPLC-QTtrap-MS).METHODS:
After pH adjustment with 2% formic acid, the urine samples were loaded on a WAX solid phase extraction (SPE) cartridge for extraction, purification and concentration. The eluates were collected, concentrated to dryness under nitrogen, and reconstituted with 10 mmol/L ammonium acetate aqueous solution-methanol ( V waterⶠV methanol = 70â¶30) before injection. UPLC was performed on a C 18 cartridge, and methanol and 10 mmol/L ammonium acetate aqueous solution was used as mobile phases with gradient elution. QTtrap-MS was operated in multiple reaction monitoring (MRM) mode, and the internal standard calibration curves were applied for quantitative analysis.RESULTS:
Good linearity was obtained in the linear range, with the method detection limits and method quantification limits being 0.032 ng/L-6.5 ng/L and 0.10 ng/L-21 ng/L, respectively, for the 12 kinds of PFCs. The spiked recoveries of the 12 kinds of PFCs were 91.5%-114%, with the intra-day precision and the inter-day precision being 0.57%-16.0% and 1.88%-20.1%, respectively. The established method was applied to the determination of 12 kinds of PFCs in the urine samples of primary school students collected in one area. Nine kinds of PFCs were detected in the urine samples in this area. Among the PFCs detected, perfluorobutanesulfonic acid (PFBS) and perfluorooctanoic acid (PFOA) were the main PFCs found in the student urine samples.CONCLUSION:
The method established in this study could be used to simultaneously examine 12 kinds of PFCs in urine. The method combined SPE with isotope internal standard correction and achieved good sensitivity and accuracy.Palavras-chave
Texto completo:
1
Coleções:
01-internacional
Base de dados:
MEDLINE
Assunto principal:
Espectrometria de Massas em Tandem
/
Extração em Fase Sólida
Limite:
Humans
Idioma:
Zh
Revista:
Sichuan Da Xue Xue Bao Yi Xue Ban
Ano de publicação:
2021
Tipo de documento:
Article
País de afiliação:
China