Your browser doesn't support javascript.
loading
Direct Q-Value Determination of the ß
Filianin, P; Lyu, C; Door, M; Blaum, K; Huang, W J; Haverkort, M; Indelicato, P; Keitel, C H; Kromer, K; Lange, D; Novikov, Y N; Rischka, A; Schüssler, R X; Schweiger, Ch; Sturm, S; Ulmer, S; Harman, Z; Eliseev, S.
Afiliação
  • Filianin P; Max-Planck-Institut für Kernphysik, 69117 Heidelberg, Germany.
  • Lyu C; Max-Planck-Institut für Kernphysik, 69117 Heidelberg, Germany.
  • Door M; Max-Planck-Institut für Kernphysik, 69117 Heidelberg, Germany.
  • Blaum K; Max-Planck-Institut für Kernphysik, 69117 Heidelberg, Germany.
  • Huang WJ; Advanced Energy Science and Technology Guangdong Laboratory, Huizhou 516003, China.
  • Haverkort M; Institute for Theoretical Physics, Heidelberg University, 69120 Heidelberg, Germany.
  • Indelicato P; The University of Sorbonne, 75006 Paris, France.
  • Keitel CH; Max-Planck-Institut für Kernphysik, 69117 Heidelberg, Germany.
  • Kromer K; Max-Planck-Institut für Kernphysik, 69117 Heidelberg, Germany.
  • Lange D; Max-Planck-Institut für Kernphysik, 69117 Heidelberg, Germany.
  • Novikov YN; Department of Physics, St Petersburg State University, St Petersburg 198504, Russia.
  • Rischka A; NRC "Kurchatov Institute"-Petersburg Nuclear Physics Institute, Gatchina 188300, Russia.
  • Schüssler RX; ARC Centre for Engineered Quantum Systems, School of Physics, The University of Sydney, NSW 2006, Australia.
  • Schweiger C; Max-Planck-Institut für Kernphysik, 69117 Heidelberg, Germany.
  • Sturm S; Max-Planck-Institut für Kernphysik, 69117 Heidelberg, Germany.
  • Ulmer S; Max-Planck-Institut für Kernphysik, 69117 Heidelberg, Germany.
  • Harman Z; Ulmer Fundamental Symmetries Laboratory, RIKEN, Wako, Saitama 351-0198, Japan.
  • Eliseev S; Max-Planck-Institut für Kernphysik, 69117 Heidelberg, Germany.
Phys Rev Lett ; 127(7): 072502, 2021 Aug 13.
Article em En | MEDLINE | ID: mdl-34459634
ABSTRACT
The cyclotron frequency ratio of ^{187}Os^{29+} to ^{187}Re^{29+} ions was measured with the Penning-trap mass spectrometer PENTATRAP. The achieved result of R=1.000 000 013 882(5) is to date the most precise such measurement performed on ions. Furthermore, the total binding-energy difference of the 29 missing electrons in Re and Os was calculated by relativistic multiconfiguration methods, yielding the value of ΔE=53.5(10) eV. Finally, using the achieved results, the mass difference between neutral ^{187}Re and ^{187}Os, i.e., the Q value of the ß^{-} decay of ^{187}Re, is determined to be 2470.9(13) eV.

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: Phys Rev Lett Ano de publicação: 2021 Tipo de documento: Article País de afiliação: Alemanha

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: Phys Rev Lett Ano de publicação: 2021 Tipo de documento: Article País de afiliação: Alemanha