Your browser doesn't support javascript.
loading
Optimized hip-knee-ankle exoskeleton assistance at a range of walking speeds.
Bryan, Gwendolyn M; Franks, Patrick W; Song, Seungmoon; Voloshina, Alexandra S; Reyes, Ricardo; O'Donovan, Meghan P; Gregorczyk, Karen N; Collins, Steven H.
Afiliação
  • Bryan GM; Department of Mechanical Engineering, Stanford University, Stanford, USA. gbryan@stanford.edu.
  • Franks PW; Department of Mechanical Engineering, Stanford University, Stanford, USA.
  • Song S; Department of Mechanical Engineering, Stanford University, Stanford, USA.
  • Voloshina AS; Mechanical and Aerospace Engineering, University of California, Irvine, USA.
  • Reyes R; Department of Mechanical Engineering, Stanford University, Stanford, USA.
  • O'Donovan MP; U.S. Army Natick Soldier Research, Development and Engineering Center, Natick, USA.
  • Gregorczyk KN; U.S. Army Natick Soldier Research, Development and Engineering Center, Natick, USA.
  • Collins SH; Department of Mechanical Engineering, Stanford University, Stanford, USA.
J Neuroeng Rehabil ; 18(1): 152, 2021 10 18.
Article em En | MEDLINE | ID: mdl-34663372
ABSTRACT

BACKGROUND:

Autonomous exoskeletons will need to be useful at a variety of walking speeds, but it is unclear how optimal hip-knee-ankle exoskeleton assistance should change with speed. Biological joint moments tend to increase with speed, and in some cases, optimized ankle exoskeleton torques follow a similar trend. Ideal hip-knee-ankle exoskeleton torque may also increase with speed. The purpose of this study was to characterize the relationship between walking speed, optimal hip-knee-ankle exoskeleton assistance, and the benefits to metabolic energy cost.

METHODS:

We optimized hip-knee-ankle exoskeleton assistance to reduce metabolic cost for three able-bodied participants walking at 1.0 m/s, 1.25 m/s and 1.5 m/s. We measured metabolic cost, muscle activity, exoskeleton assistance and kinematics. We performed Friedman's tests to analyze trends across walking speeds and paired t-tests to determine if changes from the unassisted conditions to the assisted conditions were significant.

RESULTS:

Exoskeleton assistance reduced the metabolic cost of walking compared to wearing the exoskeleton with no torque applied by 26%, 47% and 50% at 1.0, 1.25 and 1.5 m/s, respectively. For all three participants, optimized exoskeleton ankle torque was the smallest for slow walking, while hip and knee torque changed slightly with speed in ways that varied across participants. Total applied positive power increased with speed for all three participants, largely due to increased joint velocities, which consistently increased with speed.

CONCLUSIONS:

Exoskeleton assistance is effective at a range of speeds and is most effective at medium and fast walking speeds. Exoskeleton assistance was less effective for slow walking, which may explain the limited success in reducing metabolic cost for patient populations through exoskeleton assistance. Exoskeleton designers may have more success when targeting activities and groups with faster walking speeds. Speed-related changes in optimized exoskeleton assistance varied by participant, indicating either the benefit of participant-specific tuning or that a wide variety of torque profiles are similarly effective.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Exoesqueleto Energizado / Velocidade de Caminhada Limite: Humans Idioma: En Revista: J Neuroeng Rehabil Assunto da revista: ENGENHARIA BIOMEDICA / NEUROLOGIA / REABILITACAO Ano de publicação: 2021 Tipo de documento: Article País de afiliação: Estados Unidos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Exoesqueleto Energizado / Velocidade de Caminhada Limite: Humans Idioma: En Revista: J Neuroeng Rehabil Assunto da revista: ENGENHARIA BIOMEDICA / NEUROLOGIA / REABILITACAO Ano de publicação: 2021 Tipo de documento: Article País de afiliação: Estados Unidos