Your browser doesn't support javascript.
loading
New Fluorescent Probes for the Sensitive Determination of Glyphosate in Food and Environmental Samples.
Sun, Fang; Yang, Liu; Li, Shijie; Wang, Yubo; Wang, Ludi; Li, Ping; Ye, Fei; Fu, Ying.
Afiliação
  • Sun F; Department of Applied Chemistry, College of Arts and Sciences, Northeast Agricultural University, Harbin 150030, People's Republic of China.
  • Yang L; Department of Applied Chemistry, College of Arts and Sciences, Northeast Agricultural University, Harbin 150030, People's Republic of China.
  • Li S; Department of Applied Chemistry, College of Arts and Sciences, Northeast Agricultural University, Harbin 150030, People's Republic of China.
  • Wang Y; Department of Applied Chemistry, College of Arts and Sciences, Northeast Agricultural University, Harbin 150030, People's Republic of China.
  • Wang L; Department of Applied Chemistry, College of Arts and Sciences, Northeast Agricultural University, Harbin 150030, People's Republic of China.
  • Li P; Department of Applied Chemistry, College of Arts and Sciences, Northeast Agricultural University, Harbin 150030, People's Republic of China.
  • Ye F; Department of Applied Chemistry, College of Arts and Sciences, Northeast Agricultural University, Harbin 150030, People's Republic of China.
  • Fu Y; Department of Applied Chemistry, College of Arts and Sciences, Northeast Agricultural University, Harbin 150030, People's Republic of China.
J Agric Food Chem ; 69(43): 12661-12673, 2021 Nov 03.
Article em En | MEDLINE | ID: mdl-34672544
ABSTRACT
In this paper, a dual-functional probe, 2-(benzothiazol)-4-(3-hydroxy-4-methylphenyl) imino phenol (BHMH), was synthesized and characterized for the simultaneous detection of Cu2+ and Fe3+ in dimethyl sulfoxide/4-(2-hydroxyethyl)-1-piperazineethanesulfonic acid (DMSO/HEPES) (14, v/v, pH = 6.0). The limits of detections (LODs) for Cu2+ and Fe3+ were 9.05 and 48 nM, respectively. Based on the competitive coordination, the complex BHMH-Cu2+/Fe3+ exhibited good sensitivity and selectivity for glyphosate. The LODs of BHMH-Cu2+ and BHMH-Fe3+ for glyphosate were 0.41 and 0.63 µM, respectively. The probe quantitatively detected glyphosate in tap water, Songhua River water, local water and soil, and food samples. The colorimetric on-site glyphosate sensing through the probe BHMH-Cu2+ was also studied based on smartphones. BHMH and BHMH-Cu2+/Fe3+ exhibited outstanding imaging capabilities for Cu2+, Fe3+, and glyphosate in living cells with low cytotoxicity, especially the first time for glyphosate.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Cobre / Corantes Fluorescentes Tipo de estudo: Diagnostic_studies Idioma: En Revista: J Agric Food Chem Ano de publicação: 2021 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Cobre / Corantes Fluorescentes Tipo de estudo: Diagnostic_studies Idioma: En Revista: J Agric Food Chem Ano de publicação: 2021 Tipo de documento: Article