Your browser doesn't support javascript.
loading
Motion capture evaluation of sagittal spino-pelvic biomechanics after lumbar spinal fusion.
Boroda, Nickolas; Pradhan, Sonia; Forsthoefel, Craig William; Mardjetko, Steven M; Bou Monsef, Jad; Amirouche, Farid.
Afiliação
  • Boroda N; Department of Orthopaedics, University of Illinois at Chicago, 835 S. Wolcott Ave, Room E270, Chicago, IL, 60612, USA.
  • Pradhan S; Department of Orthopaedics, University of Illinois at Chicago, 835 S. Wolcott Ave, Room E270, Chicago, IL, 60612, USA.
  • Forsthoefel CW; Department of Orthopaedics, University of Illinois at Chicago, 835 S. Wolcott Ave, Room E270, Chicago, IL, 60612, USA.
  • Mardjetko SM; Department of Orthopaedics, University of Illinois at Chicago, 835 S. Wolcott Ave, Room E270, Chicago, IL, 60612, USA.
  • Bou Monsef J; Department of Orthopaedic Surgery and Rehabilitation Medicine, SUNY Downstate Health Sciences University, Brooklyn, NY, USA.
  • Amirouche F; Department of Orthopaedics, University of Illinois at Chicago, 835 S. Wolcott Ave, Room E270, Chicago, IL, 60612, USA. amirouch@uic.edu.
Spine Deform ; 10(3): 473-478, 2022 05.
Article em En | MEDLINE | ID: mdl-34981456
PURPOSE: The spine and pelvis coexist as a dynamic linked system in which spinal and pelvic parameters are correlated. Investigation of this system can inform the understanding and treatment of spinal deformity. Here, we demonstrate the use of motion capture technology to measure spine biomechanical parameters using a novel testing apparatus. METHODS: Three complete cadaveric spines with skull and pelvis were mounted into a biomechanical testing apparatus. Each lumbar vertebra was monitored by motion capture cameras as the spines underwent maximal anterior and posterior pelvic tilts about two sagittal axes at a controlled speed and applied force. These axes were defined as the sacral axis which passes transversely through the ilium and S1, and the acetabular axis which passes transversely through both acetabula. The experiments were repeated after L4-L5 fusion, and then, after both L4-L5 and T12-S1 fusion with pedicle screw instrumentation. Data were collected for total range of motion and for coupled translation at each functional spinal unit (FSU). RESULTS: Total range of motion and coupled translation within functional spinal units (FSUs) was decreased after spinal fusion. The displacement of each individual FSU was captured and summarized along with the observed patterns under each experimental condition. CONCLUSION: Lumbar fusion decreases spinal motion in the sagittal plane in both overall ROM and individual coupled translations of lumbar vertebrae. This was demonstrated using motion capture technology which is useful for quantifying the translations of individual FSUs in a multisegmental spinal model.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Fusão Vertebral Limite: Humans Idioma: En Revista: Spine Deform Ano de publicação: 2022 Tipo de documento: Article País de afiliação: Estados Unidos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Fusão Vertebral Limite: Humans Idioma: En Revista: Spine Deform Ano de publicação: 2022 Tipo de documento: Article País de afiliação: Estados Unidos