Your browser doesn't support javascript.
loading
F-18 meta-fluorobenzylguanidine PET imaging of myocardial sympathetic innervation.
Grkovski, Milan; Zanzonico, Pat B; Modak, Shakeel; Humm, John L; Narula, Jagat; Pandit-Taskar, Neeta.
Afiliação
  • Grkovski M; Department of Medical Physics, Memorial Sloan Kettering Cancer Center, New York, NY, USA.
  • Zanzonico PB; Department of Medical Physics, Memorial Sloan Kettering Cancer Center, New York, NY, USA.
  • Modak S; Department of Pediatrics, Memorial Sloan Kettering Cancer Center, New York, NY, USA.
  • Humm JL; Department of Medical Physics, Memorial Sloan Kettering Cancer Center, New York, NY, USA.
  • Narula J; Mount Sinai Heart, The Mount Sinai Hospital, New York, NY, USA.
  • Pandit-Taskar N; Icahn School of Medicine at Mount Sinai, New York, NY, USA.
J Nucl Cardiol ; 29(6): 3179-3188, 2022 12.
Article em En | MEDLINE | ID: mdl-34993893
BACKGROUND: I-123 meta-iodobenzylguanidine (MIBG) imaging has long been employed to noninvasively assess the integrity of human norepinephrine transporter-1 and, hence, myocardial sympathetic innervation. Positron-emitting F-18 meta-fluorobenzylguanidine (MFBG) has recently been developed for potentially superior quantitative characterization. We assessed the feasibility of MFBG imaging of myocardial sympathetic innervation. METHODS: 16 patients were imaged with MFBG PET (30-minute dynamic imaging of chest, followed by 3 whole-body acquisitions between 30 minutes and 4-hour post-injection). Blood kinetics were assessed from multiple samples. Pharmacokinetic modeling with reversible 1- and 2-compartment models was performed. Kinetic rate constants were re-calculated from truncated datasets. All patients underwent concurrent MIBG SPECT. RESULTS: MFBG myocardial uptake was rapid and sustained; the mean standardized uptake value (SUV (mean ± standard deviation)) was 5.1 ± 2.2 and 3.4 ± 1.9 at 1 hour and 3-4-hour post-injection, respectively. The mean K1 and distribution volume (VT) were 1.1 ± 0.6 mL/min/g and 34 ± 22 mL/cm3, respectively. Both were reproducible when re-calculated from truncated 1-hour datasets (Intraclass Correlation Coefficient of 0.99 and 0.91, respectively). Spearman's ϱ = 0.86 between MFBG SUV and VT and 0.80 between MFBG PET-derived VT and MIBG SPECT-derived heart-to-mediastinum activity concentration ratio. CONCLUSION: MFBG is a promising PET radiotracer for the assessment of myocardial sympathetic innervation.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Compostos Radiofarmacêuticos / 3-Iodobenzilguanidina Limite: Humans Idioma: En Revista: J Nucl Cardiol Assunto da revista: CARDIOLOGIA Ano de publicação: 2022 Tipo de documento: Article País de afiliação: Estados Unidos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Compostos Radiofarmacêuticos / 3-Iodobenzilguanidina Limite: Humans Idioma: En Revista: J Nucl Cardiol Assunto da revista: CARDIOLOGIA Ano de publicação: 2022 Tipo de documento: Article País de afiliação: Estados Unidos