Your browser doesn't support javascript.
loading
An electrochemical sensor based on copper-based metal-organic framework-reduced graphene oxide composites for determination of 2,4-dichlorophenol in water.
Nguyen, Manh B; Hong Nhung, Vu Thi; Thu, Vu Thi; Ngoc Nga, Dau Thi; Pham Truong, Thuan Nguyen; Giang, Hoang Truong; Hai Yen, Pham Thi; Phong, Pham Hong; Vu, Tuan A; Thu Ha, Vu Thi.
Afiliação
  • Nguyen MB; Institute of Chemistry (IoC), Vietnam Academy of Science and Technology (VAST) 18 Hoang Quoc Viet, Cau Giay Hanoi Vietnam Havt@ich.vast.vn.
  • Hong Nhung VT; Institute of Chemistry (IoC), Vietnam Academy of Science and Technology (VAST) 18 Hoang Quoc Viet, Cau Giay Hanoi Vietnam Havt@ich.vast.vn.
  • Thu VT; University of Science and Technology of Hanoi (USTH), Vietnam Academy of Science and Technology (VAST) 18 Hoang Quoc Viet, Cau Giay Hanoi Vietnam thuvu.edu86@gmail.com.
  • Ngoc Nga DT; University of Science and Technology of Hanoi (USTH), Vietnam Academy of Science and Technology (VAST) 18 Hoang Quoc Viet, Cau Giay Hanoi Vietnam thuvu.edu86@gmail.com.
  • Pham Truong TN; CY Cergy Paris University, LPPI 5 Mail Gay Lussac F-95000 Cergy France.
  • Giang HT; University of Science and Technology of Hanoi (USTH), Vietnam Academy of Science and Technology (VAST) 18 Hoang Quoc Viet, Cau Giay Hanoi Vietnam thuvu.edu86@gmail.com.
  • Hai Yen PT; Institute of Chemistry (IoC), Vietnam Academy of Science and Technology (VAST) 18 Hoang Quoc Viet, Cau Giay Hanoi Vietnam Havt@ich.vast.vn.
  • Phong PH; Institute of Chemistry (IoC), Vietnam Academy of Science and Technology (VAST) 18 Hoang Quoc Viet, Cau Giay Hanoi Vietnam Havt@ich.vast.vn.
  • Vu TA; Institute of Chemistry (IoC), Vietnam Academy of Science and Technology (VAST) 18 Hoang Quoc Viet, Cau Giay Hanoi Vietnam Havt@ich.vast.vn.
  • Thu Ha VT; Institute of Chemistry (IoC), Vietnam Academy of Science and Technology (VAST) 18 Hoang Quoc Viet, Cau Giay Hanoi Vietnam Havt@ich.vast.vn.
RSC Adv ; 10(69): 42212-42220, 2020 Nov 17.
Article em En | MEDLINE | ID: mdl-35516768
ABSTRACT
In the present work, we reported the fabrication of a novel electrochemical sensing platform to detect 2,4-dichlorophenol (2,4-DCP) by using a copper benzene-1,3,5-tricarboxylate-graphene oxide (Cu-BTC/GO) composite. The sensor was prepared by drop-casting Cu-BTC/GO suspension onto the electrode surface followed by electrochemical reduction, leading to the generation of an electrochemically reduced graphene oxide network (ErGO). By combining the large specific area of the Cu-BTC matrix with the electrical percolation from the graphene network, the number of accessible reaction sites was strongly increased, which consequently improved the detection performance. The electrochemical characteristics of the composite were revealed by cyclic voltammetry and electrochemical impedance spectroscopy. For the detection of 2,4-DCP, differential pulse voltammetry was used to emphasize the faradaic reaction related to the oxidation of the analyte. The results displayed a low detection limit (83 × 10-9 M) and a linear range from 1.5 × 10-6 M to 24 × 10-6 M alongside high reproducibility (RSD = 2.5% for eight independent sensors) and good stability. Importantly, the prepared sensors were sufficiently selective against interference from other pollutants in the same electrochemical window. Notably, the presented sensors have already proven their ability in detecting 2,4-DCP in real field samples with high accuracy (recovery range = 97.17-104.15%).

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: RSC Adv Ano de publicação: 2020 Tipo de documento: Article