A sensitive electrochemical sensor based on ZIF-8-acetylene black-chitosan nanocomposites for rutin detection.
Jin, Ya-Feng; Ge, Chuang-Ye; Li, Xiao-Bo; Zhang, Miao; Xu, Guang-Ri; Li, Dong-Hao.
Afiliação
  • Jin YF; Key Laboratory of Natural Resources of the Changbai Mountain and Functional Molecular (Yanbian University), Ministry of Education Park Road 977 Yanji City Jilin Province 133002 China dhli6510@126.com.
  • Ge CY; Department of Chemistry and Chemical Engineering, Henan Institute of Science and Technology Xinxiang 453003 China xugr70@163.com +86-0373-3693027.
  • Li XB; Department of Chemistry and Chemical Engineering, Henan Institute of Science and Technology Xinxiang 453003 China xugr70@163.com +86-0373-3693027.
  • Zhang M; Department of Chemistry and Chemical Engineering, Henan Institute of Science and Technology Xinxiang 453003 China xugr70@163.com +86-0373-3693027.
  • Xu GR; State Key Laboratory of Luminescent Materials and Devices, South China University of Technology Guangzhou 510641 P. R. China.
  • Li DH; Department of Chemistry and Chemical Engineering, Henan Institute of Science and Technology Xinxiang 453003 China xugr70@163.com +86-0373-3693027.
RSC Adv ; 8(57): 32740-32746, 2018 Sep 18.
Article em En | MEDLINE | ID: mdl-35547678
ABSTRACT
Herein, we fabricated a sensitive rutin electrochemical sensor via modifying glassy carbon electrode (GCE) with zeolitic imidazolate framework-8 (ZIF-8) and acetylene black (AB) in the presence of chitosan (CS). The electrochemical activity and experimental parameters of the ZIF-8-AB-CS/GCE sensor were investigated by cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS). Under the optimal conditions, the sensor presented a reasonable linear response in the range of 0.1-10 µM with a limit of detection (LOD) as low as 0.004 µM (S/N = 3). The sensor possessed good reproducibility and high stability, and was successfully applied to detect rutin tablet samples with satisfactory results, which was attributed to the synergistic effect between ZIF-8 and AB. Meanwhile, the sensor displayed a potential application for detection of other analytes in real samples. Furthermore, a probable interaction mechanism was proposed to account for the interaction between rutin and the nanocomposite electrode, which was not discussed in previous reports.