Your browser doesn't support javascript.
loading
Marker-Free, Molecule Sensitive Mapping of Disturbed Falling Fluid Films Using Raman Imaging.
Nachtmann, Marcel; Feger, Daniel; Sold, Sebastian; Wühler, Felix; Scholl, Stephan; Rädle, Matthias.
Afiliação
  • Nachtmann M; Center for Mass Spectrometery and Optical Spectroscopy, Hochschule Mannheim University of Applied Sciences, 68163 Mannheim, Germany.
  • Feger D; Center for Mass Spectrometery and Optical Spectroscopy, Hochschule Mannheim University of Applied Sciences, 68163 Mannheim, Germany.
  • Sold S; Center for Mass Spectrometery and Optical Spectroscopy, Hochschule Mannheim University of Applied Sciences, 68163 Mannheim, Germany.
  • Wühler F; Center for Mass Spectrometery and Optical Spectroscopy, Hochschule Mannheim University of Applied Sciences, 68163 Mannheim, Germany.
  • Scholl S; Institute for Chemical and Thermal Process Engineering, Technische Universität Braunschweig, 38106 Braunschweig, Germany.
  • Rädle M; Center for Mass Spectrometery and Optical Spectroscopy, Hochschule Mannheim University of Applied Sciences, 68163 Mannheim, Germany.
Sensors (Basel) ; 22(11)2022 May 27.
Article em En | MEDLINE | ID: mdl-35684704
Technical liquid flow films are the basic arrangement for gas fluid transitions of all kinds and are the basis of many chemical processes, such as columns, evaporators, dryers, and different other kinds of fluid/fluid separation units. This publication presents a new method for molecule sensitive, non-contact, and marker-free localized concentration mapping in vertical falling films. Using Raman spectroscopy, no label or marker is needed for the detection of the local composition in liquid mixtures. In the presented cases, the film mapping of sodium sulfate in water on a plain surface as well as an added artificial streaming disruptor with the shape of a small pyramid is scanned in three dimensions. The results show, as a prove of concept, a clear detectable spectroscopic difference between air, back plate, and sodium sulfate for every local point in all three dimensions. In conclusion, contactless Raman scanning on falling films for liquid mapping is realizable without any mechanical film interaction caused by the measuring probe. Surface gloss or optical reflections from a metallic back plate are suppressed by using only inelastic light scattering and the mathematical removal of background noise.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Análise Espectral Raman / Diagnóstico por Imagem Tipo de estudo: Diagnostic_studies Idioma: En Revista: Sensors (Basel) Ano de publicação: 2022 Tipo de documento: Article País de afiliação: Alemanha

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Análise Espectral Raman / Diagnóstico por Imagem Tipo de estudo: Diagnostic_studies Idioma: En Revista: Sensors (Basel) Ano de publicação: 2022 Tipo de documento: Article País de afiliação: Alemanha