Your browser doesn't support javascript.
loading
Two-site evaluation of the Roche Elecsys Vitamin D total III assay.
Favresse, Julien; Schiettecatte, Johan; Wolff, Fleur; Cotton, Frederic; Elsen, Marc; Eucher, Christine; Rosseels, Catherine; Anckaert, Ellen.
Afiliação
  • Favresse J; Department of Laboratory Medicine, Clinique St-Luc Bouge, Namur, Belgium.
  • Schiettecatte J; Department of Pharmacy, Namur Research Institute for Life Sciences, University of Namur, Namur, Belgium.
  • Wolff F; Department of Clinical Chemistry and Radioimmunology, Vrije Universiteit Brussel, Universitair Ziekenhuis Brussel (UZ Brussel), Brussels, Belgium.
  • Cotton F; Department of Clinical Chemistry, LHUB-ULB, Université Libre de Bruxelles, Brussels, Belgium.
  • Elsen M; Department of Clinical Chemistry, LHUB-ULB, Université Libre de Bruxelles, Brussels, Belgium.
  • Eucher C; Department of Laboratory Medicine, Clinique St-Luc Bouge, Namur, Belgium.
  • Rosseels C; Department of Laboratory Medicine, Clinique St-Luc Bouge, Namur, Belgium.
  • Anckaert E; Department of Laboratory Medicine, Clinique St-Luc Bouge, Namur, Belgium.
Clin Chem Lab Med ; 60(10): 1598-1606, 2022 09 27.
Article em En | MEDLINE | ID: mdl-35849629
ABSTRACT

OBJECTIVES:

The high request for vitamin D testing in the last decades has led manufacturers to develop assays on automated immunoassay platforms. The objective of this study was to evaluate the performance of the new Elecsys Vitamin D total III assay for the measurement of total 25(OH)D.

METHODS:

A total of 844 serum samples collected in two clinical laboratories were used to evaluate the new Roche Elecsys Vitamin D total III assay. Comparisons with Roche Elecsys Vitamin D total II and liquid chromatography tandem mass spectrometry (LC-MS/MS) were carried out. Additionally, assay imprecision, linearity, matrix effects, biotin interference, cross-reactivity with 24,25(OH)2D3 and 3-epi-25(OH)D3, and outlier rate were evaluated for the Elecsys Vitamin D total III assay.

RESULTS:

Only the comparison between LC-MS/MS and Roche Elecsys Vitamin D total III achieved the optimal specification for bias (i.e., <3.4%). Imprecision, linearity and matrix effects showed acceptable results. The biotin interference threshold was increased up to 1,200 ng/mL and the outlier rate was low (0.26%). The cross-reactivity with 24,25(OH)2D3 and 3-epi-25(OH)D3 was weak or modest in available patient samples. However, using SRM972a with a high level of 3-epi-25(OH)D3 (enriched) revealed an important cross-reactivity with both Roche Elecsys Vitamin D total II and III assays (+74.7% and +73.7%).

CONCLUSIONS:

In conclusion, the Roche Elecsys Vitamin D total III assay presents several advantages compared to the previous assay generation higher biotin interference threshold, broader measuring range, and better comparability with LC-MS/MS. However, the cross-reactivity toward 3-epi-25(OH)D3 is still problematic in high titer samples.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Vitamina D / Espectrometria de Massas em Tandem Limite: Humans Idioma: En Revista: Clin Chem Lab Med Assunto da revista: QUIMICA CLINICA / TECNICAS E PROCEDIMENTOS DE LABORATORIO Ano de publicação: 2022 Tipo de documento: Article País de afiliação: Bélgica

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Vitamina D / Espectrometria de Massas em Tandem Limite: Humans Idioma: En Revista: Clin Chem Lab Med Assunto da revista: QUIMICA CLINICA / TECNICAS E PROCEDIMENTOS DE LABORATORIO Ano de publicação: 2022 Tipo de documento: Article País de afiliação: Bélgica