Your browser doesn't support javascript.
loading
Design and optimization of an IgG human ELISA assay reactive to recombinant RBD SARS-CoV-2 protein.
Rodríguez, María Celeste; Ceaglio, Natalia; Gugliotta, Agustina; Villarraza, Javier; Garay, Ernesto; Fuselli, Antonela; Gastaldi, Victoria; Tardivo, María Belén; Antuña, Sebastián; Fontana, Diego; Prieto, Claudio.
Afiliação
  • Rodríguez MC; UNL, CONICET, FBCB (School of Biochemistry and Biological Sciences), CBL (Biotechnological Center of Litoral), Cell Culture Laboratory, Ciudad Universitaria, Ruta Nacional 168 - Km 472.4 - C.C. 242 - (S3000ZAA), Santa Fe, Argentina. rodriguezmaceleste@gmail.com.
  • Ceaglio N; UNL, CONICET, FBCB (School of Biochemistry and Biological Sciences), CBL (Biotechnological Center of Litoral), Cell Culture Laboratory, Ciudad Universitaria, Ruta Nacional 168 - Km 472.4 - C.C. 242 - (S3000ZAA), Santa Fe, Argentina.
  • Gugliotta A; UNL, CONICET, FBCB (School of Biochemistry and Biological Sciences), CBL (Biotechnological Center of Litoral), Cell Culture Laboratory, Ciudad Universitaria, Ruta Nacional 168 - Km 472.4 - C.C. 242 - (S3000ZAA), Santa Fe, Argentina.
  • Villarraza J; UNL, CONICET, FBCB (School of Biochemistry and Biological Sciences), CBL (Biotechnological Center of Litoral), Cell Culture Laboratory, Ciudad Universitaria, Ruta Nacional 168 - Km 472.4 - C.C. 242 - (S3000ZAA), Santa Fe, Argentina.
  • Garay E; UNL, CONICET, FBCB (School of Biochemistry and Biological Sciences), CBL (Biotechnological Center of Litoral), Cell Culture Laboratory, Ciudad Universitaria, Ruta Nacional 168 - Km 472.4 - C.C. 242 - (S3000ZAA), Santa Fe, Argentina.
  • Fuselli A; UNL, CONICET, FBCB (School of Biochemistry and Biological Sciences), CBL (Biotechnological Center of Litoral), Cell Culture Laboratory, Ciudad Universitaria, Ruta Nacional 168 - Km 472.4 - C.C. 242 - (S3000ZAA), Santa Fe, Argentina.
  • Gastaldi V; UNL, CONICET, FBCB (School of Biochemistry and Biological Sciences), CBL (Biotechnological Center of Litoral), Cell Culture Laboratory, Ciudad Universitaria, Ruta Nacional 168 - Km 472.4 - C.C. 242 - (S3000ZAA), Santa Fe, Argentina.
  • Tardivo MB; Biotecnofe S.A. PTLC, Ruta 168 Pje El Pozo (3000), Santa Fe, Argentina.
  • Antuña S; Biotecnofe S.A. PTLC, Ruta 168 Pje El Pozo (3000), Santa Fe, Argentina.
  • Fontana D; Biotecnofe S.A. PTLC, Ruta 168 Pje El Pozo (3000), Santa Fe, Argentina.
  • Prieto C; UNL, CONICET, FBCB (School of Biochemistry and Biological Sciences), CBL (Biotechnological Center of Litoral), Cell Culture Laboratory, Ciudad Universitaria, Ruta Nacional 168 - Km 472.4 - C.C. 242 - (S3000ZAA), Santa Fe, Argentina.
Appl Microbiol Biotechnol ; 106(23): 7933-7948, 2022 Dec.
Article em En | MEDLINE | ID: mdl-36329132
ABSTRACT
Serology assays are essential tools to mitigate the effect of COVID-19, help to identify previous SARS-CoV-2 infections or vaccination, and provide data for surveillance and epidemiologic studies. In this study, we report the production and purification process of the receptor-binding domain (RBD) of SARS-CoV-2 in HEK293 cells, which allowed the design, optimization, and validation of an indirect ELISA (iELISA) for the detection of human anti-RBD antibodies. To find the optimal conditions of this iELISA, a multivariate strategy was performed throughout design of experiments (DoE) and response surface methodology (RSM), one of the main tools of quality by design (QbD) approach. The adoption of this strategy helped to reduce the time and cost during the method development stage and to define an optimum condition within the analyzed design region. The assay was then validated, exhibiting a sensitivity of 94.24 (86.01-98.42%; 95% CI) and a specificity of 95.96% (89.98-98.89%; 95% CI). Besides, the degree of agreement between quality results assessed using kappa's value was 0.92. Hence, this iELISA represents a high-throughput technique, simple to perform, reliable, and feasible to be scaled up to satisfy the current demands. Since RBD is proposed as the coating antigen, the intended use of this iELISA is not only the detection of previous exposure to the virus, but also the possibility of detecting protective immunity. KEY POINTS • RBD was produced in 1-L bioreactor and highly purified. • An iELISA assay was optimized applying QbD concepts. • The validation procedure demonstrated that this iELISA is accurate and precise.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: SARS-CoV-2 / COVID-19 Tipo de estudo: Diagnostic_studies / Prognostic_studies Limite: Humans Idioma: En Revista: Appl Microbiol Biotechnol Ano de publicação: 2022 Tipo de documento: Article País de afiliação: Argentina

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: SARS-CoV-2 / COVID-19 Tipo de estudo: Diagnostic_studies / Prognostic_studies Limite: Humans Idioma: En Revista: Appl Microbiol Biotechnol Ano de publicação: 2022 Tipo de documento: Article País de afiliação: Argentina