Your browser doesn't support javascript.
loading
Final 5-Year Report of the Randomized BIO-RESORT Trial Comparing 3 Contemporary Drug-Eluting Stents in All-Comers.
Ploumen, Eline H; Pinxterhuis, Tineke H; Buiten, Rosaly A; Zocca, Paolo; Danse, Peter W; Schotborgh, Carl E; Scholte, Martijn; Gin, R Melvyn Tjon Joe; Somi, Samer; van Houwelingen, K Gert; Stoel, Martin G; de Man, H A F; Hartmann, Marc; Linssen, Gerard C M; van der Heijden, Liefke C; Kok, Marlies M; Doggen, Carine J M; von Birgelen, Clemens.
Afiliação
  • Ploumen EH; Department of Cardiology Thoraxcentrum Twente, Medisch Spectrum Twente Enschede The Netherlands.
  • Pinxterhuis TH; Department of Health Technology and Services Research, Faculty BMS Technical Medical Centre, University of Twente Enschede The Netherlands.
  • Buiten RA; Department of Cardiology Thoraxcentrum Twente, Medisch Spectrum Twente Enschede The Netherlands.
  • Zocca P; Department of Health Technology and Services Research, Faculty BMS Technical Medical Centre, University of Twente Enschede The Netherlands.
  • Danse PW; Department of Cardiology Thoraxcentrum Twente, Medisch Spectrum Twente Enschede The Netherlands.
  • Schotborgh CE; Department of Cardiology Thoraxcentrum Twente, Medisch Spectrum Twente Enschede The Netherlands.
  • Scholte M; Department of Cardiology Rijnstate Hospital Arnhem The Netherlands.
  • Gin RMTJ; Department of Cardiology Haga Hospital The Hague The Netherlands.
  • Somi S; Department of Cardiology Albert Schweitzer Hospital Dordrecht The Netherlands.
  • van Houwelingen KG; Department of Cardiology Rijnstate Hospital Arnhem The Netherlands.
  • Stoel MG; Department of Cardiology Haga Hospital The Hague The Netherlands.
  • de Man HAF; Department of Cardiology Thoraxcentrum Twente, Medisch Spectrum Twente Enschede The Netherlands.
  • Hartmann M; Department of Cardiology Thoraxcentrum Twente, Medisch Spectrum Twente Enschede The Netherlands.
  • Linssen GCM; Department of Cardiology Thoraxcentrum Twente, Medisch Spectrum Twente Enschede The Netherlands.
  • van der Heijden LC; Department of Cardiology Thoraxcentrum Twente, Medisch Spectrum Twente Enschede The Netherlands.
  • Kok MM; Department of Cardiology Hospital Group Twente Almelo, Hengelo The Netherlands.
  • Doggen CJM; Department of Cardiology Thoraxcentrum Twente, Medisch Spectrum Twente Enschede The Netherlands.
  • von Birgelen C; Department of Cardiology Thoraxcentrum Twente, Medisch Spectrum Twente Enschede The Netherlands.
J Am Heart Assoc ; 11(22): e026041, 2022 11 15.
Article em En | MEDLINE | ID: mdl-36346050
ABSTRACT
Background In a previous trial, higher 5-year mortality was observed following treatment with biodegradable polymer Orsiro sirolimus-eluting stents (SES). We assessed 5-year safety and efficacy of all-comers as well as patients with diabetes treated with SES or Synergy everolimus-eluting stents (EES) versus durable polymer Resolute Integrity zotarolimus-eluting stents (ZES). Methods and Results The randomized BIO-RESORT (Comparison of Biodegradable Polymer and Durable Polymer Drug-Eluting Stents in an All Comers Population) trial enrolled 3514 all-comer patients at 4 Dutch cardiac centers. Patients aged ≥18 years who required percutaneous coronary intervention were eligible. Participants were stratified for diabetes and randomized to treatment with SES, EES, or ZES (111). The main end point was target vessel failure (cardiac mortality, target vessel myocardial infarction, or target vessel revascularization). Five-year follow-up was available in 3183 of 3514 (90.6%) patients. The main end point target vessel failure occurred in 142 of 1169 (12.7%) patients treated with SES, 130 of 1172 (11.6%) treated with EES, versus 157 of 1173 (14.1%) treated with ZES (hazard ratio [HR], 0.89 [95% CI, 0.71-1.12], Plog-rank=0.31; and HR, 0.82 [95% CI, 0.65-1.04], Plog-rank=0.10, respectively). Individual components of target vessel failure showed no significant between-stent difference. Very late definite stent thrombosis rates were low and similar (SES, 1.1%; EES, 0.6%; ZES, 0.9%). In patients with diabetes, target vessel failure did not differ significantly between stent-groups (SES, 19.8%; EES, 19.2%; versus ZES, 21.1% [Plog-rank=0.69 and Plog-rank=0.63]). Conclusions Orsiro SES, Synergy EES, and Resolute Integrity ZES showed similar 5-year outcomes of safety and efficacy, including mortality. A prespecified stent comparison in patients with diabetes also revealed no significant differences in 5-year clinical outcomes. Registration URL https//www.clinicaltrials.gov; Unique identifier NCT01674803.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Doença da Artéria Coronariana / Diabetes Mellitus / Stents Farmacológicos / Intervenção Coronária Percutânea Tipo de estudo: Clinical_trials / Etiology_studies Limite: Adolescent / Adult / Humans Idioma: En Revista: J Am Heart Assoc Ano de publicação: 2022 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Doença da Artéria Coronariana / Diabetes Mellitus / Stents Farmacológicos / Intervenção Coronária Percutânea Tipo de estudo: Clinical_trials / Etiology_studies Limite: Adolescent / Adult / Humans Idioma: En Revista: J Am Heart Assoc Ano de publicação: 2022 Tipo de documento: Article