Your browser doesn't support javascript.
loading
Validated HPLC-UV method for quantification of paxalisib, a pan PI3K and mTOR inhibitor in mouse plasma: Application to a pharmacokinetic study in mice.
Zakkula, Ashok; Tripathy, Harsha K; Bestha, Rama Murthi; Vinod, A B; Kiran, Vinay; Dittakavi, Sreekanth; Mullangi, Ramesh.
Afiliação
  • Zakkula A; Drug Metabolism and Pharmacokinetics, Laxai Life Sciences Pvt. Ltd, Shamirpet, Hyderabad, India.
  • Tripathy HK; Karnataka College of Pharmacy, Thirumenahalli, Bangalore, India.
  • Bestha RM; Drug Metabolism and Pharmacokinetics, Laxai Life Sciences Pvt. Ltd, Shamirpet, Hyderabad, India.
  • Vinod AB; Drug Metabolism and Pharmacokinetics, Laxai Life Sciences Pvt. Ltd, Shamirpet, Hyderabad, India.
  • Kiran V; Drug Metabolism and Pharmacokinetics, Laxai Life Sciences Pvt. Ltd, Shamirpet, Hyderabad, India.
  • Dittakavi S; Drug Metabolism and Pharmacokinetics, Laxai Life Sciences Pvt. Ltd, Shamirpet, Hyderabad, India.
  • Mullangi R; Drug Metabolism and Pharmacokinetics, Laxai Life Sciences Pvt. Ltd, Shamirpet, Hyderabad, India.
Biomed Chromatogr ; 37(4): e5587, 2023 Apr.
Article em En | MEDLINE | ID: mdl-36680551
ABSTRACT
Paxalisib is a pan-PI3K and mTOR inhibitor, currently entering into Phase II clinical trials as a potential drug to treat glioblastoma patients. We report the development and validation of a high-performance liquid chromatography (HPLC) method for the quantitation of paxalisib in mouse plasma as per the US Food and Drug Administration regulatory guidelines. From the mouse plasma, paxalisib and the internal standard (IS; filgotinib) were extracted using ethyl acetate as an extraction solvent. The chromatographic separation of paxalisib and the IS was accomplished on a Symmetry C18 (250 × 4.6 mm, 5.0 µm) column maintained at 40°C using 10 mm ammonium formate and acetonitrile in gradient conditions at a 0.8 ml/min flow-rate. The injection volume was 20 µl. The elution was monitored using a photo-diode array detector set at λmax 280 nm. Paxalisib and the IS eluted at 6.5 and 5.9 min, respectively with a total run time of 10 min. The calibration curve was linear over the range of 111-4,989 ng/ml. Inter- and intraday precision and accuracy, stability studies, dilution integrity and incurred sample reanalysis were investigated and the results met the acceptance criteria. The validated HPLC method was extended to assess the pharmacokinetic parameters of paxalisib in mice.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Fosfatidilinositol 3-Quinases / Inibidores de Proteínas Quinases Tipo de estudo: Guideline Limite: Animals Idioma: En Revista: Biomed Chromatogr Ano de publicação: 2023 Tipo de documento: Article País de afiliação: Índia

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Fosfatidilinositol 3-Quinases / Inibidores de Proteínas Quinases Tipo de estudo: Guideline Limite: Animals Idioma: En Revista: Biomed Chromatogr Ano de publicação: 2023 Tipo de documento: Article País de afiliação: Índia