Your browser doesn't support javascript.
loading
A comparative study between 10-MHz and 15-MHz ultrasound probes for retinal evaluation in silicone-oil-filled globes.
Albadawi, Maha A; Allam, Riham S H M; Khalil, Noha M M; Eissa, Iman M.
Afiliação
  • Albadawi MA; Department of Ophthalmology, Faculty of Medicine, Kasr Al Ainy School of Medicine, Cairo University, Cairo, Egypt.
  • Allam RSHM; Department of Ophthalmology, Faculty of Medicine, Kasr Al Ainy School of Medicine, Cairo University, Cairo, Egypt. ryham_allam@cu.edu.eg.
  • Khalil NMM; Department of Ophthalmology, Faculty of Medicine, Kasr Al Ainy School of Medicine, Cairo University, Cairo, Egypt.
  • Eissa IM; Department of Ophthalmology, Faculty of Medicine, Kasr Al Ainy School of Medicine, Cairo University, Cairo, Egypt.
Eye (Lond) ; 37(14): 3020-3025, 2023 10.
Article em En | MEDLINE | ID: mdl-36879162
PURPOSE: To compare 10-MHz and 15-MHz B-scan probes regarding the detection and localization of retinal detachment (RD) in silicone-oil-filled eyes. METHODS: This cross-sectional observational study included 100 eyes (98 patients) -having media opacity precluding fundus examination- scheduled for silicone-oil removal. Patients were examined in the sitting-position using both frequencies one week preoperatively. Longitudinal and transverse scans were taken in primary-gaze, inferior, inferonasal, and inferotemporal positions to detect the presence/absence and extent of RD. Patients were sub-grouped according to axial lengths (AXLs), state of silicone emulsification, and globe filling. Agreement between sonographic and intraoperative observations was compared. RESULTS: No statistically significant differences were found between 15-MHz and intra-operative findings regarding RD detection (P = 0.752) and accurate localization of inferior, inferonasal, and inferotemporal RD (P = 0.279, 0.606, and 0.599). There were statistically significant differences between 10-MHz and intra-operative findings regarding RD detection and localization (P < 0.001). The 15-MHz probe was superior to 10-MHz probe regarding the accuracy of RD detection and localization (94% and 47%, respectively). The accuracy of 15-MHz probe was 88%, 83%, and 85% in detecting and localizing inferior, inferonasal, and inferotemporal RD compared to 45%, 60%, and 62% with 10-MHz probe. The 15-MHz probe showed better sensitivity while 10-MHz probe showed better accuracy in eyes with short AXLs. The 10-MHz probe showed better sensitivity in patients with sonographic emulsification while15-MHz probe had better sensitivity in detecting vitreoretinal-interface disorders. CONCLUSION: The 15-MHz B-scan probe is more accurate in detecting and localizing recurrent RD in silicone-oil-filled globes with higher sensitivity in detecting vitreoretinal-interface disorders.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Óleos de Silicone / Descolamento Retiniano Tipo de estudo: Observational_studies / Prevalence_studies / Risk_factors_studies Limite: Humans Idioma: En Revista: Eye (Lond) Assunto da revista: OFTALMOLOGIA Ano de publicação: 2023 Tipo de documento: Article País de afiliação: Egito

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Óleos de Silicone / Descolamento Retiniano Tipo de estudo: Observational_studies / Prevalence_studies / Risk_factors_studies Limite: Humans Idioma: En Revista: Eye (Lond) Assunto da revista: OFTALMOLOGIA Ano de publicação: 2023 Tipo de documento: Article País de afiliação: Egito