Your browser doesn't support javascript.
loading
Endoscopic mucosal resection of gastrointestinal polyps with a novel low-temperature plasma radio frequency generator: a non-inferiority multi-center randomized control study.
Cai, Ming-Yan; Zhu, Liang; Xu, Xiao-Yue; Xu, Jia-Xin; Zhang, Dan-Feng; Zhang, Zhen; Li, Quan-Lin; Qin, Wen-Zheng; Feng, Li; Xu, Jian-Guang; Li, Peng; Zhou, Ping-Hong.
Afiliação
  • Cai MY; Shanghai Collaborative Innovation Center of Endoscopy, Endoscopy Center and Endoscopy Research Institute, Zhongshan Hospital of Fudan University, 180 Fenglin Road, Shanghai, 200032, China.
  • Zhu L; Shanghai Collaborative Innovation Center of Endoscopy, Endoscopy Center and Endoscopy Research Institute, Zhongshan Hospital of Fudan University, 180 Fenglin Road, Shanghai, 200032, China.
  • Xu XY; Shanghai Collaborative Innovation Center of Endoscopy, Endoscopy Center and Endoscopy Research Institute, Zhongshan Hospital of Fudan University, 180 Fenglin Road, Shanghai, 200032, China.
  • Xu JX; Shanghai Collaborative Innovation Center of Endoscopy, Endoscopy Center and Endoscopy Research Institute, Zhongshan Hospital of Fudan University, 180 Fenglin Road, Shanghai, 200032, China.
  • Zhang DF; Shanghai Collaborative Innovation Center of Endoscopy, Endoscopy Center and Endoscopy Research Institute, Zhongshan Hospital of Fudan University, 180 Fenglin Road, Shanghai, 200032, China.
  • Zhang Z; Shanghai Collaborative Innovation Center of Endoscopy, Endoscopy Center and Endoscopy Research Institute, Zhongshan Hospital of Fudan University, 180 Fenglin Road, Shanghai, 200032, China.
  • Li QL; Shanghai Collaborative Innovation Center of Endoscopy, Endoscopy Center and Endoscopy Research Institute, Zhongshan Hospital of Fudan University, 180 Fenglin Road, Shanghai, 200032, China.
  • Qin WZ; Shanghai Collaborative Innovation Center of Endoscopy, Endoscopy Center and Endoscopy Research Institute, Zhongshan Hospital of Fudan University, 180 Fenglin Road, Shanghai, 200032, China.
  • Feng L; Department of Gastroenterology, Central Hospital of Minhang District, Shanghai, China.
  • Xu JG; Department of Gastroenterology, Quzhou People's Hospital, Zhejiang, China.
  • Li P; Department of Gastroenterology, Beijing Friendship Hospital, Capital Medical University, Beijing, China.
  • Zhou PH; Shanghai Collaborative Innovation Center of Endoscopy, Endoscopy Center and Endoscopy Research Institute, Zhongshan Hospital of Fudan University, 180 Fenglin Road, Shanghai, 200032, China. zhou.pinghong@zs-hospital.sh.cn.
Surg Endosc ; 37(4): 3272-3279, 2023 04.
Article em En | MEDLINE | ID: mdl-36890416
ABSTRACT

BACKGROUND:

To evaluate the efficacy and safety of novel plasma radio frequency generator and its single-use polypectomy snares for endoscopic mucosal resection (EMR) of gastrointestinal (GI) polyps.

METHODS:

A total of 217 patients with 413 GI polyps were recruited from four centers in China. Patients were assigned to experimental or control groups using a central randomization method. The experimental group used the novel plasma radio frequency generator and its matched single-use polypectomy snares (Neowing, Shanghai), while the control group used the high-frequency electrosurgical unit (Erbe, Germany) and disposable electrosurgical snares (Olympus, Japan). The primary endpoint was the en bloc resection rate, and the non-inferiority margin was set at 10%. Secondary endpoint included operation time, coagulation success rate, intraoperative and postoperative bleeding rate, and perforation rate.

RESULTS:

The en bloc resection rate was 97.20% (104/107) in the experimental group and 95.45% (105/110) in the control group (P = 0.496). The operation time was 29.14 ± 20.21 min in the experimental group and 30.26 ± 18.74 min in the control group (P = 0.671). The average removal time of a single polyp in the experimental group was 7.52 ± 4.45 min, which was slightly shorter than that in the control group 8.90 ± 6.67 min, with no statistical difference (P = 0.076). The intraoperative bleeding rates of the experimental group and control group were 8.41% (9/107) and 10.00% (11/110), respectively (P = 0.686). No intraoperative perforation occurred in either group. The postoperative bleeding rates of the experimental group and the control group were 1.87% (2/107) and 4.55% (5/110), respectively (P = 0.465). No postoperative perforation occurred in the experimental group (0/107), while one case of delayed perforation occurred in the control group (1/110, 0.91%). There was no statistical difference between the two groups.

CONCLUSIONS:

Endoscopic mucosal resection of GI polyps with the novel plasma radio frequency generator is safe and effective, and non-inferior to the conventional high-frequency electrosurgical system.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Pólipos do Colo / Ressecção Endoscópica de Mucosa / Neoplasias Gastrointestinais Tipo de estudo: Clinical_trials Limite: Humans País/Região como assunto: Asia Idioma: En Revista: Surg Endosc Assunto da revista: DIAGNOSTICO POR IMAGEM / GASTROENTEROLOGIA Ano de publicação: 2023 Tipo de documento: Article País de afiliação: China

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Pólipos do Colo / Ressecção Endoscópica de Mucosa / Neoplasias Gastrointestinais Tipo de estudo: Clinical_trials Limite: Humans País/Região como assunto: Asia Idioma: En Revista: Surg Endosc Assunto da revista: DIAGNOSTICO POR IMAGEM / GASTROENTEROLOGIA Ano de publicação: 2023 Tipo de documento: Article País de afiliação: China