Your browser doesn't support javascript.
loading
Mapping the 3D position of battery cathode particles in Bragg coherent diffractive imaging.
Shabalin, A G; Zhang, M; Yao, W; Rysov, R; Ren, Z; Lapkin, D; Kim, Y Y; Assalauova, D; Mukharamova, N; Sprung, M; Vartanyants, I A; Meng, Y S; Shpyrko, O G.
Afiliação
  • Shabalin AG; Department of Physics, University of California San Diego, La Jolla, CA 92093-0319, USA.
  • Zhang M; Department of NanoEngineering, University of California San Diego, La Jolla, CA 92093-0448, USA.
  • Yao W; Department of NanoEngineering, University of California San Diego, La Jolla, CA 92093-0448, USA.
  • Rysov R; Deutsches Elektronen-Synchrotron DESY, Notkestrasse 85, 22607 Hamburg, Germany.
  • Ren Z; Deutsches Elektronen-Synchrotron DESY, Notkestrasse 85, 22607 Hamburg, Germany.
  • Lapkin D; Deutsches Elektronen-Synchrotron DESY, Notkestrasse 85, 22607 Hamburg, Germany.
  • Kim YY; Deutsches Elektronen-Synchrotron DESY, Notkestrasse 85, 22607 Hamburg, Germany.
  • Assalauova D; Deutsches Elektronen-Synchrotron DESY, Notkestrasse 85, 22607 Hamburg, Germany.
  • Mukharamova N; Deutsches Elektronen-Synchrotron DESY, Notkestrasse 85, 22607 Hamburg, Germany.
  • Sprung M; Deutsches Elektronen-Synchrotron DESY, Notkestrasse 85, 22607 Hamburg, Germany.
  • Vartanyants IA; Deutsches Elektronen-Synchrotron DESY, Notkestrasse 85, 22607 Hamburg, Germany.
  • Meng YS; Department of NanoEngineering, University of California San Diego, La Jolla, CA 92093-0448, USA.
  • Shpyrko OG; Department of Physics, University of California San Diego, La Jolla, CA 92093-0319, USA.
J Synchrotron Radiat ; 30(Pt 2): 445-448, 2023 Mar 01.
Article em En | MEDLINE | ID: mdl-36891858
In Bragg coherent diffractive imaging, the precise location of the measured crystals in the interior of the sample is usually missing. Obtaining this information would help the study of the spatially dependent behavior of particles in the bulk of inhomogeneous samples, such as extra-thick battery cathodes. This work presents an approach to determine the 3D position of particles by precisely aligning them at the instrument axis of rotation. In the test experiment reported here, with a 60 µm-thick LiNi0.5Mn1.5O4 battery cathode, the particles were located with a precision of 20 µm in the out-of-plane direction, and the in-plane coordinates were determined with a precision of 1 µm.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: J Synchrotron Radiat Assunto da revista: RADIOLOGIA Ano de publicação: 2023 Tipo de documento: Article País de afiliação: Estados Unidos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: J Synchrotron Radiat Assunto da revista: RADIOLOGIA Ano de publicação: 2023 Tipo de documento: Article País de afiliação: Estados Unidos