Your browser doesn't support javascript.
loading
Engineered tenorite structure of barium-enriched copper oxide for on-site monitoring of cytotoxic methotrexate in environmental samples.
Yamuna, Annamalai; Karikalan, Natarajan; Lee, Dain; Lee, Tae Yoon.
Afiliação
  • Yamuna A; Department of Biomedical Engineering and Department of Convergence System Engineering, Chungnam National University, Daejeon 34134, Republic of Korea.
  • Karikalan N; Department of Biomedical Engineering and Department of Convergence System Engineering, Chungnam National University, Daejeon 34134, Republic of Korea.
  • Lee D; Department of Technology Education, Chungnam National University, Daejeon 34134, Republic of Korea.
  • Lee TY; Department of Biomedical Engineering and Department of Convergence System Engineering, Chungnam National University, Daejeon 34134, Republic of Korea; Department of Technology Education, Chungnam National University, Daejeon 34134, Republic of Korea. Electronic address: taeyoon.lee@cnu.ac.kr.
J Hazard Mater ; 451: 131158, 2023 06 05.
Article em En | MEDLINE | ID: mdl-36921414
ABSTRACT
Emerging pharmaceutical pollutants pose a threat to both human and environmental health. The removal and monitoring of such pollutants necessitate the use of practical on-site monitoring devices; however, the designs of such devices are underdeveloped. This study involves the fabrication of a low-cost sensor based on barium-incorporated copper oxide (Ba-CuO) for the on-site monitoring of the cytotoxic drug methotrexate (MTRX) in water and sediment samples. The tenorite structure of CuO was slightly enriched with Ba ions at the td sites, distorting the tetrahedron and enhancing its electrochemical properties. Ba-CuO was obtained from Cu(NO3)2 and Ba(OH)2 by a ligand exchange protocol and was characterized using X-ray diffraction, Raman spectroscopy, X-ray photoelectron spectroscopy, field-emission scanning electron microscopy, transmission electron microscopy, and energy dispersive X-ray analysis. In addition, the Ba-CuO sensor was tested under various conditions, and it could detect MTRX at concentrations as low as 0.4 nM, with a high sensitivity of 1.3567 µA µM-1 cm-2. On-site monitoring yielded recoveries of greater than 93 % from spiked samples, thus exhibiting excellent reproducibility and stability. Therefore, the developed method is practical and has no matrix effect on the MTRX sensor.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Metotrexato / Antineoplásicos Tipo de estudo: Guideline Limite: Humans Idioma: En Revista: J Hazard Mater Assunto da revista: SAUDE AMBIENTAL Ano de publicação: 2023 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Metotrexato / Antineoplásicos Tipo de estudo: Guideline Limite: Humans Idioma: En Revista: J Hazard Mater Assunto da revista: SAUDE AMBIENTAL Ano de publicação: 2023 Tipo de documento: Article