Mechanical ventilation with ten versus twenty breaths per minute during cardio-pulmonary resuscitation for out-of-hospital cardiac arrest: A randomised controlled trial.
Prause, Gerhard; Zoidl, Philipp; Eichinger, Michael; Eichlseder, Michael; Orlob, Simon; Ruhdorfer, Felix; Honnef, Gabriel; Metnitz, Philipp G H; Zajic, Paul.
Afiliação
  • Prause G; Division of General Anaesthesiology, Emergency- and Intensive Care Medicine, Medical University of Graz, Graz, Austria.
  • Zoidl P; Division of General Anaesthesiology, Emergency- and Intensive Care Medicine, Medical University of Graz, Graz, Austria. Electronic address: https://twitter.com/PhZoidl.
  • Eichinger M; Division of General Anaesthesiology, Emergency- and Intensive Care Medicine, Medical University of Graz, Graz, Austria.
  • Eichlseder M; Division of General Anaesthesiology, Emergency- and Intensive Care Medicine, Medical University of Graz, Graz, Austria.
  • Orlob S; Division of Anaesthesiology for Cardiovascular Surgery and Intensive Care Medicine, Medical University of Graz, Graz, Austria.
  • Ruhdorfer F; Division of General Anaesthesiology, Emergency- and Intensive Care Medicine, Medical University of Graz, Graz, Austria.
  • Honnef G; Division of General Anaesthesiology, Emergency- and Intensive Care Medicine, Medical University of Graz, Graz, Austria.
  • Metnitz PGH; Division of General Anaesthesiology, Emergency- and Intensive Care Medicine, Medical University of Graz, Graz, Austria.
  • Zajic P; Division of General Anaesthesiology, Emergency- and Intensive Care Medicine, Medical University of Graz, Graz, Austria.
Resuscitation ; 187: 109765, 2023 06.
Article em En | MEDLINE | ID: mdl-36931453
ABSTRACT
AIM OF THE STUDY This study sought to assess the effects of increasing the ventilatory rate from 10 min-1 to 20 min-1 using a mechanical ventilator during cardio-pulmonary resuscitation (CPR) for out-of-hospital cardiac arrest (OHCA) on ventilation, acid-base-status, and outcomes.

METHODS:

This was a randomised, controlled, single-centre trial in adult patients receiving CPR including advanced airway management and mechanical ventilation offered by staff of a prehospital physician response unit (PRU). Ventilation was conducted using a turbine-driven ventilator (volume-controlled ventilation, tidal volume 6 ml per kg of ideal body weight, positive end-expiratory pressure (PEEP) 0 mmHg, inspiratory oxygen fraction (FiO2) 100%), frequency was pre-set at either 10 or 20 breaths per minute according to week of randomisation. If possible, an arterial line was placed and blood gas analysis was performed.

RESULTS:

The study was terminated early due to slow recruitment. 46 patients (23 per group) were included. Patients in the 20 min-1 group received higher expiratory minute volumes [8.8 (6.8-9.9) vs. 4.9 (4.2-5.7) litres, p < 0.001] without higher mean airway pressures [11.6 (9.8-13.6) vs. 9.8 (8.5-12.0) mmHg, p = 0.496] or peak airway pressures [42.5 (36.5-45.9) vs. 41.4 (32.2-51.7) mmHg, p = 0.895]. Rates of ROSC [12 of 23 (52%) vs. 11 of 23 (48%), p = 0.768], median pH [6.83 (6.65-7.05) vs. 6.89 (6.80-6.97), p = 0.913], and median pCO2 [78 (51-105) vs. 86 (73-107) mmHg, p > 0.999] did not differ between groups.

CONCLUSION:

20 instead of 10 mechanical ventilations during CPR increase ventilation volumes per minute, but do not improve CO2 washout, acidaemia, oxygenation, or rate of ROSC. CLINICALTRIALS gov Identifier NCT04657393.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Reanimação Cardiopulmonar / Parada Cardíaca Extra-Hospitalar Tipo de estudo: Clinical_trials Limite: Adult / Humans Idioma: En Revista: Resuscitation Ano de publicação: 2023 Tipo de documento: Article País de afiliação: Áustria

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Reanimação Cardiopulmonar / Parada Cardíaca Extra-Hospitalar Tipo de estudo: Clinical_trials Limite: Adult / Humans Idioma: En Revista: Resuscitation Ano de publicação: 2023 Tipo de documento: Article País de afiliação: Áustria