Your browser doesn't support javascript.
loading
Influence of sampling frequency and estimation method on phosphorus load uncertainty in the Western Lake Erie Basin, Ohio, USA.
Kamrath, Brock; Yuan, Yongping; Manning, Nathan; Johnson, Laura.
Afiliação
  • Kamrath B; Oak Ridge Institute for Science and Education (ORISE) Postdoctoral Research Participant at U.S. Environmental Protection Agency, Research Triangle Park, NC.
  • Yuan Y; USEPA, Office of Research and Development, Research Triangle Park, NC.
  • Manning N; National Center for Water Quality Research, Heidelburg University, Tiffin, OH.
  • Johnson L; National Center for Water Quality Research, Heidelburg University, Tiffin, OH.
J Hydrol (Amst) ; 617(B): 1-11, 2023 Feb 01.
Article em En | MEDLINE | ID: mdl-37006458
ABSTRACT
Accurate estimates of nutrient loads are necessary to identify critical source areas and quantify the impact of management practices on pollutant export. Previous studies have investigated nutrient load estimate uncertainty, but they often focus on nutrient loads estimated using an interpolation method for large-scale watersheds with short-term datasets. The study objective was to quantify uncertainty in soluble reactive phosphorus (SRP), total phosphorus (TP), and suspended solids (SS) load estimates from two small (<103 km2) agricultural watersheds in the western Lake Erie Basin resulting from different sampling frequencies. Each watershed had high temporal resolution datasets of discharge (15 min) and nutrient concentration (1 to 3 samples per day) collected over a 30-year period (1990-2020). Firstly, SRP, TP, and SS loads were calculated using the high temporal resolution datasets, which was assumed as "true loads". Secondly, the high temporal concentration data were decomposed to semiweekly, weekly, biweekly, and monthly sampling and annual loads were estimated using four common load estimation methods to assess the effect of sampling frequency and load estimation method on load estimate error. Across the four different methods, the composite method had the lowest relative root mean square and absolute bias, but the rectangular interpolation method was the most precise. However, even with semiweekly sampling, the composite method resulted in an unacceptable level of precision (average imprecision = 39 %), while the interpolation method resulted in an unacceptable bias (average absolute bias = 16 %). Because neither method could provide acceptable accuracy and precision at the lowest decrease in sampling (e.t. semiweekly sampling), continued daily sampling is recommended in these watersheds.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: J Hydrol (Amst) Ano de publicação: 2023 Tipo de documento: Article País de afiliação: Nova Caledônia

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: J Hydrol (Amst) Ano de publicação: 2023 Tipo de documento: Article País de afiliação: Nova Caledônia