Your browser doesn't support javascript.
loading
Endometrioid adenocarcinoma: combined multiparametric MRI and tumour marker HE4 to evaluate tumour grade and lymphovascular space invasion.
Yue, X N; He, X Y; Wu, J J; Fan, W; Zhang, H J; Wang, C W.
Afiliação
  • Yue XN; Department of CT/MRI, First Affiliated Hospital of Shihezi University, Shihezi, Xinjiang, 832000, China.
  • He XY; Department of CT/MRI, First Affiliated Hospital of Shihezi University, Shihezi, Xinjiang, 832000, China.
  • Wu JJ; Department of CT/MRI, First Affiliated Hospital of Shihezi University, Shihezi, Xinjiang, 832000, China.
  • Fan W; Department of CT/MRI, First Affiliated Hospital of Shihezi University, Shihezi, Xinjiang, 832000, China.
  • Zhang HJ; Department of Pathology, First Affiliated Hospital of Shihezi University, Shihezi, Xinjiang, 832000, China.
  • Wang CW; Department of CT/MRI, First Affiliated Hospital of Shihezi University, Shihezi, Xinjiang, 832000, China. Electronic address: 2214757292@qq.com.
Clin Radiol ; 78(8): e574-e581, 2023 08.
Article em En | MEDLINE | ID: mdl-37183140
ABSTRACT

AIM:

To assess the value of semi-quantitative dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) and quantitative diffusion-weighted imaging parameters combined with human epididymis protein 4 (HE4) in predicting the pathological grade and lymphovascular space invasion (LVSI) of endometrioid adenocarcinoma (EAC). MATERIALS AND

METHODS:

Between October 2018 and December 2021, 60 women (mean age, 55 [range, 32-77] years) with EAC underwent preoperative pelvic MRI and HE4 level measurements. The positive enhancement integral (PEI), time to peak, maximum slope of increase (MSI), and maximum slope of decrease were measured by manually drawing a region of interest on the neoplastic tissue. The receiver operating characteristic curve was used to calculate the diagnostic efficiency of the single parameter and combined factors.

RESULTS:

Lower apparent diffusion coefficients (ADCs) were observed in high-grade tumours (G3) than in low-grade tumours (G1/G2). PEI, MSI, and HE4 levels were higher in the high-grade tumours than in the low-grade tumours (p<0.05). The area under the curve (AUC) for G3 diagnosis using multiparametric MRI combined with HE4 was 0.929. ADC values were significantly lower in the EAC with LVSI than in those without LVSI. Tumours with LVSI showed higher PEI and HE4 levels than those without LVSI (p<0.05). The AUC for LVSI-positive diagnosis using multiparametric MRI combined with HE4 was 0.814.

CONCLUSION:

Semi-quantitative DCE-MRI, ADC values, and serum HE4 levels can be used to predict tumour grade and LVSI, and the prediction efficiency of multiparametric MRI combined with serum HE4 is better than that of any single factor.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Carcinoma Endometrioide / Imageamento por Ressonância Magnética Multiparamétrica Tipo de estudo: Observational_studies / Prognostic_studies / Risk_factors_studies Limite: Adult / Aged / Female / Humans / Middle aged Idioma: En Revista: Clin Radiol Ano de publicação: 2023 Tipo de documento: Article País de afiliação: China

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Carcinoma Endometrioide / Imageamento por Ressonância Magnética Multiparamétrica Tipo de estudo: Observational_studies / Prognostic_studies / Risk_factors_studies Limite: Adult / Aged / Female / Humans / Middle aged Idioma: En Revista: Clin Radiol Ano de publicação: 2023 Tipo de documento: Article País de afiliação: China