Your browser doesn't support javascript.
loading
A Novel Polyurethane-Based Polyion Complex Material with Tunable Selectivity against Interferents for Selective Dopamine Determination.
Zhang, Zixin; Guo, Hongchen; Hirai, Yuugo; Takeda, Katsunori; Asai, Chiho; Takamura, Naohiro; Niwa, Osamu.
Afiliação
  • Zhang Z; Advanced Science Research Laboratory, Saitama Institute of Technology, 1690, Fusaiji, Fukaya, Saitama 369-0293, Japan.
  • Guo H; Department of Life Science and Green Chemistry, Graduate School of Engineering, Saitama Institute of Technology, 1690, Fusaiji, Fukaya, Saitama 369-0293, Japan.
  • Hirai Y; Department of Life Science and Green Chemistry, Graduate School of Engineering, Saitama Institute of Technology, 1690, Fusaiji, Fukaya, Saitama 369-0293, Japan.
  • Takeda K; R&D Headquarters, DKS Co., Ltd., 5 Ogawara, Kisshoin, Minami, Kyoto 601-8391, Japan.
  • Asai C; R&D Headquarters, DKS Co., Ltd., 5 Ogawara, Kisshoin, Minami, Kyoto 601-8391, Japan.
  • Takamura N; R&D Headquarters, DKS Co., Ltd., 5 Ogawara, Kisshoin, Minami, Kyoto 601-8391, Japan.
  • Niwa O; Advanced Science Research Laboratory, Saitama Institute of Technology, 1690, Fusaiji, Fukaya, Saitama 369-0293, Japan.
Biosensors (Basel) ; 13(6)2023 Jun 09.
Article em En | MEDLINE | ID: mdl-37367003
ABSTRACT
Polyion complex (PIC) materials have been widely used in biosensors due to their molecular selectivity. However, achieving both widely controllable molecular selectivity and long-term solution stability with traditional PIC materials has been challenging due to the different molecular structures of polycations (poly-C) and polyanions (poly-A). To address this issue, we propose a novel polyurethane (PU)-based PIC material in which the main chains of both poly-A and poly-C are composed of PU structures. In this study, we electrochemically detect dopamine (DA) as the analyte and L-ascorbic acid (AA) and uric acid (UA) as the interferents to evaluate the selective property of our material. The results show that AA and UA are significantly eliminated, while DA can be detected with a high sensitivity and selectivity. Moreover, we successfully tune the sensitivity and selectivity by changing the poly-A and poly-C ratios and adding nonionic polyurethane. These excellent results were employed in the development of a highly selective DA biosensor with a detection range from 500 nM to 100 µM and a 3.4 µM detection limit. Overall, our novel PIC-modified electrode has the potential to advance biosensing technologies for molecular detection.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Técnicas Biossensoriais / Dopamina Idioma: En Revista: Biosensors (Basel) Ano de publicação: 2023 Tipo de documento: Article País de afiliação: Japão

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Técnicas Biossensoriais / Dopamina Idioma: En Revista: Biosensors (Basel) Ano de publicação: 2023 Tipo de documento: Article País de afiliação: Japão