Your browser doesn't support javascript.
loading
Use of Real-Time Cine MRI to Assess the Respirophasic Variation of the Inferior Vena Cava-Proof-of-Concept and Validation Against Transthoracic Echocardiography.
Bogaert, Jan; Bekhuis, Youri; Rosseel, Thomas; Laveaux, Stijn; Dausin, Christophe; Voigt, Jens-Uwe; Claessen, Guido; Dresselaers, Tom.
Afiliação
  • Bogaert J; Department of Radiology, UZ Leuven, Leuven, Belgium.
  • Bekhuis Y; Department of Imaging and Pathology, KU Leuven, Leuven, Belgium.
  • Rosseel T; Department of Cardiology, UZ Leuven, Leuven, Belgium.
  • Laveaux S; Department of Cardiovascular Sciences, KU Leuven, Leuven, Belgium.
  • Dausin C; Department of Cardiology, UZ Leuven, Leuven, Belgium.
  • Voigt JU; Department of Radiology, UZ Leuven, Leuven, Belgium.
  • Claessen G; Department of Movement Sciences, KU Leuven, Leuven, Belgium.
  • Dresselaers T; Department of Cardiology, UZ Leuven, Leuven, Belgium.
J Magn Reson Imaging ; 59(5): 1809-1817, 2024 May.
Article em En | MEDLINE | ID: mdl-37427759
ABSTRACT

BACKGROUND:

In clinical practice, the right heart filling status is assessed using the respirophasic variation of the inferior vena cava (IVC) assessed by transthoracic echocardiography (TTE) showing moderate correlations with the catheter-based reference standard.

PURPOSE:

To develop and validate a similar approach using MRI. STUDY TYPE Prospective. POPULATION 37 male elite cyclists (mean age 26 ± 4 years). FIELD STRENGTH/SEQUENCE Real-time balanced steady-state free-precession cine sequence at 1.5 Tesla. ASSESSMENT Respirophasic variation included assessment of expiratory size of the upper hepatic part of the IVC and degree of inspiratory collapse expressed as collapsibility index (CI). The IVC was studied either in long-axis direction (TTE) or using two transverse slices, separated by 30 mm (MRI) during operator-guided deep breathing. For MRI, in addition to the TTE-like diameter, IVC area and major and minor axis diameters were also assessed, together with the corresponding CIs. STATISTICAL TESTS Repeated measures ANOVA test with Bonferroni correction. Intraclass correlation coefficient (ICC) and Bland-Altman analysis for intrareader and inter-reader agreement. A P value <0.05 was considered statistically significant.

RESULTS:

No significant differences in expiratory IVC diameter were found between TTE and MRI, i.e., 25 ± 4 mm vs. 25 ± 3 mm (P = 0.242), but MRI showed a higher CI, i.e., 76% ± 14% vs. 66% ± 14% (P < 0.05). As the IVC presented a noncircular shape, i.e., major and minor expiratory diameter of 28 ± 4 mm and 21 ± 4 mm, respectively, the CI varied according to the orientation, i.e., 63% ± 27% vs. 75% ± 16%, respectively. Alternatively, expiratory IVC area was 4.3 ± 1.1 cm2 and showed a significantly higher CI, i.e., 86% ± 14% than diameter-based CI (P < 0.05). All participants showed a CI >50% with MRI versus 35/37 (94%) with TTE. ICC values ranged 0.546-0.841 for MRI and 0.545-0.704 for TTE.

CONCLUSION:

Assessment of the respirophasic IVC variation is feasible with MRI. Adding this biomarker may be of particular use in evaluating heart failure patients. LEVEL OF EVIDENCE 1 TECHNICAL EFFICACY STAGE 2.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Veia Cava Inferior / Imagem Cinética por Ressonância Magnética Limite: Adult / Humans / Male Idioma: En Revista: J Magn Reson Imaging Assunto da revista: DIAGNOSTICO POR IMAGEM Ano de publicação: 2024 Tipo de documento: Article País de afiliação: Bélgica

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Veia Cava Inferior / Imagem Cinética por Ressonância Magnética Limite: Adult / Humans / Male Idioma: En Revista: J Magn Reson Imaging Assunto da revista: DIAGNOSTICO POR IMAGEM Ano de publicação: 2024 Tipo de documento: Article País de afiliação: Bélgica