Effect of matrix properties on transmission and reflectance mode division-of-focal-plane Stokes polarimetry.
Iannucci, Leanne E; Riak, Matthew B; Meitz, Ethan; Bersi, Matthew R; Gruev, Viktor; Lake, Spencer P.
Afiliação
  • Iannucci LE; Washington University in St. Louis, McKelvey School of Engineering, Department of Biomedical Engineering, St. Louis, Missouri, United States.
  • Riak MB; Washington University in St. Louis, McKelvey School of Engineering, Department of Mechanical Engineering and Materials Science, St. Louis, Missouri, United States.
  • Meitz E; Washington University in St. Louis, McKelvey School of Engineering, Department of Mechanical Engineering and Materials Science, St. Louis, Missouri, United States.
  • Bersi MR; Washington University in St. Louis, McKelvey School of Engineering, Department of Mechanical Engineering and Materials Science, St. Louis, Missouri, United States.
  • Gruev V; University of Illinois Urbana-Champaign, Department of Electrical and Computer Engineering, Champaign, Illinois, United States.
  • Lake SP; Washington University in St. Louis, McKelvey School of Engineering, Department of Biomedical Engineering, St. Louis, Missouri, United States.
J Biomed Opt ; 28(10): 102902, 2023 10.
Article em En | MEDLINE | ID: mdl-37441242
ABSTRACT

Significance:

Division-of-focal-plane Stokes polarimetry is emerging as a powerful tool for the microstructural characterization of soft tissues. How individual extracellular matrix (ECM) properties influence polarimetric signals in reflectance or transmission modes of quantitative polarized light imaging (QPLI) is not well understood.

Aim:

We aimed to investigate how ECM properties affect outcomes obtained from division-of-focal-plane polarimetric imaging in reflectance or transmission modes.

Approach:

Tunable collagen gel phantoms were used to modulate ECM properties of anisotropy, collagen density, crosslinking, and absorber density; the effects of degree of linear polarization (DoLP) and angle of polarization (AoP) on polarimetry outcomes were assessed. A model biological tissue (i.e., bovine tendon) was similarly imaged and evaluated using both reflectance and transmission modes.

Results:

Reflectance QPLI resulted in decreased DoLP compared with transmission mode. A 90 deg shift in AoP was observed between modes but yielded similar spatial patterns. Collagen density had the largest effect on outcomes besides anisotropy in both imaging modes.

Conclusions:

Both imaging modes were sufficiently sensitive to detect structural anisotropy differences in gels of varying fiber alignment. Conclusions drawn from phantom experiments should carry over when interpreting data from more complex tissues and can help provide context for interpretation of other Stokes polarimetry data.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Diagnóstico por Imagem / Colágeno Tipo de estudo: Diagnostic_studies Limite: Animals Idioma: En Revista: J Biomed Opt Assunto da revista: ENGENHARIA BIOMEDICA / OFTALMOLOGIA Ano de publicação: 2023 Tipo de documento: Article País de afiliação: Estados Unidos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Diagnóstico por Imagem / Colágeno Tipo de estudo: Diagnostic_studies Limite: Animals Idioma: En Revista: J Biomed Opt Assunto da revista: ENGENHARIA BIOMEDICA / OFTALMOLOGIA Ano de publicação: 2023 Tipo de documento: Article País de afiliação: Estados Unidos