Your browser doesn't support javascript.
loading
Safety in Senhance™ Robotic Gastrointestinal Surgery in 530 Patients.
Staib, Ludger; Poth, Clemens; Schilcher, Florian; Hansen, Olaf; Menke, Vivianda; Stephan, Dietmar; Willeke, Frank.
Afiliação
  • Staib L; Department of General and Visceral Surgery, Klinikum Esslingen, Esslingen, Germany.
  • Poth C; Department of General and Visceral Surgery, Klinikum Esslingen, Esslingen, Germany.
  • Schilcher F; Department of General and Visceral Surgery, Klinikum Esslingen, Esslingen, Germany.
  • Hansen O; Department of General, Visceral, and Oncologic Surgery, Evangelisches Krankenhaus, Wesel, Germany.
  • Menke V; Department of General, Visceral, and Oncologic Surgery, Evangelisches Krankenhaus, Wesel, Germany.
  • Stephan D; Minimally Invasive and Robotic Surgery, St.-Marien-Krankenhaus, Siegen, Germany.
  • Willeke F; Clinic for General and Visceral Surgery, St.- Marien-Krankenhaus, Siegen, Germany.
Surg Technol Int ; 422023 07 18.
Article em En | MEDLINE | ID: mdl-37463485
ABSTRACT
The Senhance Robotic System™ (Asensus Surgical, Durham, NC, USA) has been used in abdominal surgery since 2016, and provides an eye-tracker for camera movement and haptic tactile feedback. Safety aspects are very important in robotic surgery, such as regarding the presence of system malfunctions and surgical outcomes. The data for robotic function in gastrointestinal surgical procedures in 530 patients (colorectal surgery, fundoplication, others) were prospectively listed in the TRUST registry after informed patient consent in three German gastrointestinal surgery centers (center A, N = 46 patients; center B, N = 457; center C, N =27). Adverse events were noted in 14.3% (76/530 patients) of the overall surgeries, with an equal distribution among the procedures. Robotic malfunctions, such as console/camera/arm malfunctions, collisions, or limited motion, were experienced in 5.5 % (29/530 patients), with some differences among the centers (A, 0.0%; B, 4.2%; C, 37%). These differences were explained in terms of team experience and case load. In conclusion, the Senhance™ Robotic System can be safely applied to routine abdominal surgery procedures.

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: Surg Technol Int Ano de publicação: 2023 Tipo de documento: Article País de afiliação: Alemanha

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: Surg Technol Int Ano de publicação: 2023 Tipo de documento: Article País de afiliação: Alemanha