Your browser doesn't support javascript.
loading
Measurement of the 134Xe(n,2n)133m,gXe and 136Xe(n,2n)135m,gXe reaction cross-sections and isomeric ratios induced by the 14.8 MeV neutrons.
Guo, Hao; Li, Qian; Zhang, Chunlei; Jiang, Liyang; Ruan, Xichao.
Afiliação
  • Guo H; China Institute of Atomic Energy, BeiJing, 102413, China.
  • Li Q; China Institute of Atomic Energy, BeiJing, 102413, China; Beijing Normal University, BeiJing, 100875, China.
  • Zhang C; Beijing Normal University, BeiJing, 100875, China. Electronic address: lei@bnu.edu.cn.
  • Jiang L; China Institute of Atomic Energy, BeiJing, 102413, China. Electronic address: Jiangly@ciae.ac.cn.
  • Ruan X; China Institute of Atomic Energy, BeiJing, 102413, China.
Appl Radiat Isot ; 200: 110948, 2023 Oct.
Article em En | MEDLINE | ID: mdl-37556935
ABSTRACT
The precise measurement of the (n, 2n) reaction cross-sections of xenon isotopes is of great significance for the diagnosis of the Inertial Confinement Fusion fuel area density ρR. The preparation of xenon samples and how they can be efficiently adsorbed to obtain an optimal reaction cross section are extremely difficult in existing experiments. This work aims to use the 93Nb(n,2n)92mNb reaction cross section as the standard to calculate the cross-sections and isomeric ratio for 134Xe(n,2n)133m,gXe and 136Xe(n,2n)135m,gXe reactions. This work also aims to explore the feasibility of adsorbent selection, the method of adsorption sample and the feasibility of the method used in the laboratory. In this paper, the Geant4 program was used to simulate and calculate the adsorption factors of activated carbon and polymer for standard 152Eu multi-line sources, so as to determine the most suitable adsorption material. Next, the GammaVision analysis software was used to observe whether the characteristic γ-rays released by other isotope reaction products of xenon in the sample and packaging material had an effect on the characteristic γ-rays of the target product. Then, the basic principle of activation method and the relative measurement principle are used to calculate the cross-sections and isomeric ratio for 134Xe(n,2n)133Xe and 136Xe(n,2n)135Xe reactions. Finally, the experimental results are compared and analyzed with the existing data in EXFOR database to verify whether the experimental method is correct.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: Appl Radiat Isot Assunto da revista: MEDICINA NUCLEAR / SAUDE AMBIENTAL Ano de publicação: 2023 Tipo de documento: Article País de afiliação: China

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: Appl Radiat Isot Assunto da revista: MEDICINA NUCLEAR / SAUDE AMBIENTAL Ano de publicação: 2023 Tipo de documento: Article País de afiliação: China