Your browser doesn't support javascript.
loading
Novel Porphyrinic Covalent Organic Polymer with Polarity-Switchable Dual Wavelength for Accurate and Sensitive Photoelectrochemical Sensing.
Dong, Qingyuan; Xing, Juan; Yuan, Ruo; Yuan, Yali.
Afiliação
  • Dong Q; Key Laboratory of Luminescence Analysis and Molecular Sensing (Southwest University), Ministry of Education, College of Chemistry and Chemical Engineering, Southwest University, Chongqing 400715, P. R. China.
  • Xing J; Key Laboratory of Luminescence Analysis and Molecular Sensing (Southwest University), Ministry of Education, College of Chemistry and Chemical Engineering, Southwest University, Chongqing 400715, P. R. China.
  • Yuan R; Key Laboratory of Luminescence Analysis and Molecular Sensing (Southwest University), Ministry of Education, College of Chemistry and Chemical Engineering, Southwest University, Chongqing 400715, P. R. China.
  • Yuan Y; Key Laboratory of Luminescence Analysis and Molecular Sensing (Southwest University), Ministry of Education, College of Chemistry and Chemical Engineering, Southwest University, Chongqing 400715, P. R. China.
Anal Chem ; 95(37): 13967-13974, 2023 09 19.
Article em En | MEDLINE | ID: mdl-37672686
Herein, we synthesized a novel porphyrinic covalent organic polymer (TPAPP-PTCA PCOP) for constructing a polarity-switchable dual-wavelength photoelectrochemical (PEC) biosensor with ferrocene (Fc) and hydrogen peroxide (H2O2) as regulator and amplifier simultaneously. Interestingly, this new PCOP possessed both n-type and p-type semiconductor characteristics, which thus enabled the appearance of a dual-polarity photocurrent at two different excitation wavelengths. Furthermore, Fc and H2O2 could readily switch the photocurrent of PCOP to the cathode and anode stemming from its efficient electron collection and donation function, respectively. Based on these, a PCOP-based PEC biosensor skillfully integrating dual wavelengths with reliable accuracy and polarity switch with high sensitivity was instituted. As a result, the developed PEC biosensor exhibited a low detection limit down to 0.089 pg mL-1 for the most powerful natural carcinogen aflatoxin M1 (AFM1) assay. Impressively, the target exhibited a completely opposite photocurrent difference to the interfering substances, and the linear correlation coefficient of the assay was improved compared to single-wavelength detection. The PEC sensing platform not only provided a basis for exploring multicharacteristic photoactive material but also innovatively developed the detection mode of the PEC biosensor.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Aflatoxina M1 / Peróxido de Hidrogênio Tipo de estudo: Diagnostic_studies Idioma: En Revista: Anal Chem Ano de publicação: 2023 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Aflatoxina M1 / Peróxido de Hidrogênio Tipo de estudo: Diagnostic_studies Idioma: En Revista: Anal Chem Ano de publicação: 2023 Tipo de documento: Article