Your browser doesn't support javascript.
loading
Dynamic evaluation of unruptured intracranial aneurysms by 4D-CT angiography: comparison with digital subtraction angiography (DSA) and surgical findings.
Yang, Liping; Gao, Xing; Gao, Chao; Xu, Shichuan; Cao, Shaodong.
Afiliação
  • Yang L; Department of PET-CT, Harbin Medical University Cancer Hospital, Harbin, China.
  • Gao X; Department of physical diagnostics, Heilongjiang Provincial Hospital, Harbin, China.
  • Gao C; Medical Imaging Department, The Fourth Affiliated Hospital of Harbin Medical University, Harbin, 150001, China.
  • Xu S; Department of medical instruments, Second Hospital of Harbin, Harbin, 150001, China. 69744792@qq.com.
  • Cao S; Medical Imaging Department, The Fourth Affiliated Hospital of Harbin Medical University, Harbin, 150001, China. shaodong_cao@163.com.
BMC Med Imaging ; 23(1): 161, 2023 10 18.
Article em En | MEDLINE | ID: mdl-37853358
ABSTRACT

BACKGROUND:

This study was to prospectively investigate the feasibility of four-dimensional computed tomography angiography (4D-CTA) with electrocardiogram-gated (ECG) reconstruction for preoperative evaluation of morphological parameters, and compared with digital subtraction angiography (DSA). We also aimed to detect pulsation in unruptured intracranial aneurysms (UIAs) by using 4D-CTA, as a potential predicting factor of growth or rupture. MATERIALS 64 patients with 64 UIAs underwent ECG-gated dynamic 4D-CTA imaging before treatment, of which 46 patients additionally underwent DSA. Original scanning data were reconstructed to produce 20 data sets of cardiac cycles with 5%-time intervals. The extent of agreement on UIAs morphological features assessed with 4D-CTA and DSA was estimated using the k coefficient of the Kappa test. The radiation doses were also calculated and compared between 4D-CTA and DSA. In the aneurysmal surgically treated in our institution, we were able to compare the surgical findings of the aneurysm wall with 4D-CTA images. We performed long-term follow-up on untreated patients.

RESULTS:

The morphological characteristics detected by 4D-CTA and DSA were consistent in aneurysm location (k = 1.0), shape (k = 0.76), maximum diameter (k = 0.94), aneurysm neck (k = 0.79) and proximity to parent and branch vessels (k = 0.85). 4D-CTA required lower radiation doses (0.32 ± 0.11 mSv) than DSA (0.84 ± 0.37 mSv, P < 0.001). Pulsation was detected in 26 of the 64 unruptured aneurysms, and all underwent neurosurgical clipping or interventional embolization. In aneurysms surgically treated in our hospital, we observed a significant correlation between 4D-CTA findings and surgical evaluation of the aneurysmal wall, in particular the irregular pulsations detected on 4D-CTA have demonstrated to correspond to dark-reddish thinner wall at surgery.

CONCLUSIONS:

In this proof-of-concept study, 4D-CTA provided real-time, non-invasive preoperative assessments of UIAs comparable to DSA. Moreover, optimal correlation between the irregular pulsation detected by 4D-CTA and the surgical findings support a possible role of this technique to identify aneurysms with a higher risk of rupture.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Aneurisma Intracraniano / Tomografia Computadorizada Quadridimensional Limite: Humans Idioma: En Revista: BMC Med Imaging Assunto da revista: DIAGNOSTICO POR IMAGEM Ano de publicação: 2023 Tipo de documento: Article País de afiliação: China

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Aneurisma Intracraniano / Tomografia Computadorizada Quadridimensional Limite: Humans Idioma: En Revista: BMC Med Imaging Assunto da revista: DIAGNOSTICO POR IMAGEM Ano de publicação: 2023 Tipo de documento: Article País de afiliação: China