Evaluating blood oxygen saturation measurements by popular fitness trackers in postoperative patients: A prospective clinical trial.
Helmer, Philipp; Rodemers, Philipp; Hottenrott, Sebastian; Leppich, Robert; Helwich, Maja; Pryss, Rüdiger; Kranke, Peter; Meybohm, Patrick; Winkler, Bernd E; Sammeth, Michael.
Afiliação
  • Helmer P; Department of Anaesthesiology, Intensive Care, Emergency and Pain Medicine, University Hospital Würzburg, Oberdürrbacher Str. 6, 97080 Würzburg, Germany.
  • Rodemers P; Department of Anaesthesiology, Intensive Care, Emergency and Pain Medicine, University Hospital Würzburg, Oberdürrbacher Str. 6, 97080 Würzburg, Germany.
  • Hottenrott S; Department of Anaesthesiology, Intensive Care, Emergency and Pain Medicine, University Hospital Würzburg, Oberdürrbacher Str. 6, 97080 Würzburg, Germany.
  • Leppich R; Department of Software Engineering, Faculty of Computer Science, University Würzburg, Am Hubland, 97074 Würzburg, Germany.
  • Helwich M; Department of Anaesthesiology, Intensive Care, Emergency and Pain Medicine, University Hospital Würzburg, Oberdürrbacher Str. 6, 97080 Würzburg, Germany.
  • Pryss R; Institute for Clinical Epidemiology and Biometry, University Würzburg, Josef-Schneider-Str. 2, 97080 Würzburg, Germany.
  • Kranke P; Department of Anaesthesiology, Intensive Care, Emergency and Pain Medicine, University Hospital Würzburg, Oberdürrbacher Str. 6, 97080 Würzburg, Germany.
  • Meybohm P; Department of Anaesthesiology, Intensive Care, Emergency and Pain Medicine, University Hospital Würzburg, Oberdürrbacher Str. 6, 97080 Würzburg, Germany.
  • Winkler BE; Department of Anaesthesiology, Intensive Care, Emergency and Pain Medicine, University Hospital Würzburg, Oberdürrbacher Str. 6, 97080 Würzburg, Germany.
  • Sammeth M; Department of Anaesthesiology, Intensive Care, Emergency and Pain Medicine, University Hospital Würzburg, Oberdürrbacher Str. 6, 97080 Würzburg, Germany.
iScience ; 26(11): 108155, 2023 Nov 17.
Article em En | MEDLINE | ID: mdl-37876822
ABSTRACT
Blood oxygen saturation is an important clinical parameter, especially in postoperative hospitalized patients, monitored in clinical practice by arterial blood gas (ABG) and/or pulse oximetry that both are not suitable for a long-term continuous monitoring of patients during the entire hospital stay, or beyond. Technological advances developed recently for consumer-grade fitness trackers could-at least in theory-help to fill in this gap, but benchmarks on the applicability and accuracy of these technologies in hospitalized patients are currently lacking. We therefore conducted at the postanaesthesia care unit under controlled settings a prospective clinical trial with 201 patients, comparing in total >1,000 oxygen blood saturation measurements by fitness trackers of three brands with the ABG gold standard and with pulse oximetry. Our results suggest that, despite of an overall still tolerable measuring accuracy, comparatively high dropout rates severely limit the possibilities of employing fitness trackers, particularly during the immediate postoperative period of hospitalized patients.