Pressure-controlled ventilation-volume guaranteed mode improves bronchial mucus transport velocity in patients during laparoscopic surgery for gynecological oncology: a randomized controlled study.
Deng, Chao; Xu, Tao; Wang, Xue-Kai; Gu, Deng-Feng.
Afiliação
  • Deng C; Department of Anesthesiology, First Affiliated Hospital, Shihezi University, Shihezi, China.
  • Xu T; Department of Rehabilitation, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China.
  • Wang XK; Department of Rehabilitation, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China. 1452793572@qq.com.
  • Gu DF; Department of Anesthesiology, First Affiliated Hospital, Shihezi University, Shihezi, China.
BMC Anesthesiol ; 23(1): 379, 2023 11 20.
Article em En | MEDLINE | ID: mdl-37986138

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Pneumoperitônio / Laparoscopia Limite: Humans Idioma: En Revista: BMC Anesthesiol Ano de publicação: 2023 Tipo de documento: Article País de afiliação: China