Your browser doesn't support javascript.
loading
Temperature to time Catch-Up: a novel procedural endpoint to predict durable pulmonary vein isolation after cryoballoon ablation of paroxysmal atrial fibrillation.
Willy, Kevin; Wolfes, Julian; Müller, Patrick; Ellermann, Christian; Dechering, Dirk; Lange, Philipp S; Rath, Benjamin; Reinke, Florian; Doldi, Florian; Güner, Fatih; Köbe, Julia; Leitz, Patrick; Frommeyer, Gerrit; Laredo, Mikael; Eckardt, Lars.
Afiliação
  • Willy K; Department of Cardiology II-Electrophysiology, University Hospital of Münster, Albert-Schweitzer-Campus 1, 48419, Münster, Germany. kevin.willy@ukmuenster.de.
  • Wolfes J; Department of Cardiology II-Electrophysiology, University Hospital of Münster, Albert-Schweitzer-Campus 1, 48419, Münster, Germany.
  • Müller P; Department of Electrophysiology, Klinikum Vest Recklinghausen, Recklinghausen, Germany.
  • Ellermann C; Department of Cardiology II-Electrophysiology, University Hospital of Münster, Albert-Schweitzer-Campus 1, 48419, Münster, Germany.
  • Dechering D; Department of Cardiology, Niels-Stensen-Kliniken Marienhospital Osnabrück, Osnabrück, Germany.
  • Lange PS; Department of Cardiology II-Electrophysiology, University Hospital of Münster, Albert-Schweitzer-Campus 1, 48419, Münster, Germany.
  • Rath B; Department of Cardiology II-Electrophysiology, University Hospital of Münster, Albert-Schweitzer-Campus 1, 48419, Münster, Germany.
  • Reinke F; Department of Cardiology II-Electrophysiology, University Hospital of Münster, Albert-Schweitzer-Campus 1, 48419, Münster, Germany.
  • Doldi F; Department of Cardiology II-Electrophysiology, University Hospital of Münster, Albert-Schweitzer-Campus 1, 48419, Münster, Germany.
  • Güner F; Department of Cardiology II-Electrophysiology, University Hospital of Münster, Albert-Schweitzer-Campus 1, 48419, Münster, Germany.
  • Köbe J; Department of Cardiology II-Electrophysiology, University Hospital of Münster, Albert-Schweitzer-Campus 1, 48419, Münster, Germany.
  • Leitz P; Department of Cardiology II-Electrophysiology, University Hospital of Münster, Albert-Schweitzer-Campus 1, 48419, Münster, Germany.
  • Frommeyer G; Department of Cardiology II-Electrophysiology, University Hospital of Münster, Albert-Schweitzer-Campus 1, 48419, Münster, Germany.
  • Laredo M; Department of Cardiology and Electrophysiology, Hôpital Pitié-Salpêtrière, Paris, France.
  • Eckardt L; Department of Cardiology II-Electrophysiology, University Hospital of Münster, Albert-Schweitzer-Campus 1, 48419, Münster, Germany.
Clin Res Cardiol ; 2023 Dec 19.
Article em En | MEDLINE | ID: mdl-38112746
ABSTRACT

BACKGROUND:

Cryoballoon ablation is a widely used single-shot technique for pulmonary vein isolation (PVI) in the treatment of paroxysmal atrial fibrillation (AF). Procedural endpoints ensuring maximal PVI durability are important.

OBJECTIVE:

To assess the performance of cryoablation procedural markers to predict long-term PVI.

METHODS:

In a single center, consecutive patients who underwent redo ablation with high-density mapping for symptomatic AF recurrence after cryoballoon ablation were included and cryoballoon procedural data were collected, including temperature values at 30 and 60 s, time to isolation, nadir temperature and the velocity of temperature decline estimated with the temperature/time catch-up point (T2T-Catch-Up) defined as positive when the freeze temperature in minus degree equals the time in seconds after cryoablation initiation (e.g. - 15 °C in the first 15 s of the ablation impulse).

RESULTS:

47 patients (62% male; 58.3 ± 11.2 years) were included. Overall, 38 (80.9%) patients had ≥ 1 reconnected PV. Among 186 PVs, 56 (30.1%; 1.2 per patient on average) were reconnected. Univariate analysis revealed T2T-Catch-Up in 103 (56%) and more frequent in durably isolated than in reconnected PVs (93 [72%] vs 10 [19%], p < 0.0001). Among binary endpoints, T2T-Catch-Up had the highest specificity (82%) and predictive value for durable PVI at redo ablation (90%). In multivariable analyses, absence of T2T-Catch-Up (Odds-ratio 0.12, 95% CI [0.05-0.31], p < 0.0001) and right superior PV (Odds-ratio 3.14, 95% CI [1.27-7.74], p = 0.01) were the only variables independently associated with PV reconnection.

CONCLUSION:

T2T-Catch-Up, a new and simple cryoballoon procedural endpoint demonstrated excellent predictive value and strong statistical association with durable PVI.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: Clin Res Cardiol / Clin. res. cardiol / Clinical research in cardiology Assunto da revista: CARDIOLOGIA Ano de publicação: 2023 Tipo de documento: Article País de afiliação: Alemanha

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: Clin Res Cardiol / Clin. res. cardiol / Clinical research in cardiology Assunto da revista: CARDIOLOGIA Ano de publicação: 2023 Tipo de documento: Article País de afiliação: Alemanha