Your browser doesn't support javascript.
loading
Reliability of recovery heart rate variability measurements as part of the Lamberts Submaximal Cycle Test and the relationship with training status in trained to elite cyclists.
Lamberts, Robert P; van Erp, Teun; Javaloyes, Alejandro; Eken, Maaike M; Langerak, Nelleke G; Tam, Nicholas.
Afiliação
  • Lamberts RP; Division of Movement Science and Exercise Therapy (MSET), Department of Exercise, Sport and Lifestyle Medicine, Faculty of Medicine and Health Sciences, Stellenbosch University, Suidwal Road, Stellenbosch, 7601, South Africa. rplam@hotmail.com.
  • van Erp T; Division of Movement Science and Exercise Therapy (MSET), Department of Exercise, Sport and Lifestyle Medicine, Faculty of Medicine and Health Sciences, Stellenbosch University, Suidwal Road, Stellenbosch, 7601, South Africa.
  • Javaloyes A; Department of Sport Science, Sports Research Centre, Miguel Hernández University of Elche, Alicante, Spain.
  • Eken MM; Institute of Sport and Exercise Medicine (ISEM), Department of Exercise, Sport and Lifestyle Medicine, Faculty of Medicine and Health Sciences, Stellenbosch University, Tygerberg, South Africa, Stellenbosch University, Tygerberg, South Africa.
  • Langerak NG; Department of Research, Sint Maartenskliniek, Nijmegen, The Netherlands.
  • Tam N; Neuroscience Institute and Division of Neurosurgery, Faculty of Health Sciences, University of Cape Town, Cape Town, South Africa.
Eur J Appl Physiol ; 124(6): 1659-1668, 2024 Jun.
Article em En | MEDLINE | ID: mdl-38198009
ABSTRACT

PURPOSE:

To determine if post-exercise heart rate variability, in the form of logged transformed root mean square of successive differences of the R-R intervals (LnRMSSD) can be measured reliably during the recovery from a submaximal cycle test and what the relationship of LnRMSSD is with training status of the cyclists.

METHODS:

Fourteen male cyclists participated in the reliability part for the study, which included performing six Lamberts Submaximal Cycle Test (LSCT), during which recovery LnRMSSD was measured over 30 s (LnRMSSD30 s), 60 s LnRMSSD60 s)and 90 s LnRMSSD90 s). In addition, fifty male and twenty female cyclists completed a peak power output (PPO) test (including VO2peak) and 40 km time trial (40 km TT) before which they performed the LSCT as a standardized warm-up. Relationships between the LnRMSSD and PPO, VO2peak and 40 km TT time were studied.

RESULTS:

Due to the design of the LSCT, submaximal heart and breathing rate were similar at the end of stage 3 of the LSCT, as well as during the recovery periods. The highest reliability was found in LnRMSSD60 s (ICC 0.97) with a typical error of the measurement (TEM 5.8%). In line with this the strongest correlations were found between LnRMSSD60 s and PPO (r = 0.93[male]; 0.85[female]), VO2peak (r = 0.71[male]; 0.63[female];) and 40 km TT (r = - 0.83[male]; - 0.63[female]).

CONCLUSIONS:

LnRMSSD60 s can be measured reliably after the LSCT and can predict PPO, VO2peak and 40 km TT performance well in trained-to-elite cyclists. These findings suggest that recovery LnRMSSD can potentially play an important role in monitoring and fine-tuning training prescriptions in trained-to-elite cyclists.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Ciclismo / Teste de Esforço / Frequência Cardíaca Tipo de estudo: Prognostic_studies Limite: Adult / Female / Humans / Male Idioma: En Revista: Eur J Appl Physiol Assunto da revista: FISIOLOGIA Ano de publicação: 2024 Tipo de documento: Article País de afiliação: África do Sul

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Ciclismo / Teste de Esforço / Frequência Cardíaca Tipo de estudo: Prognostic_studies Limite: Adult / Female / Humans / Male Idioma: En Revista: Eur J Appl Physiol Assunto da revista: FISIOLOGIA Ano de publicação: 2024 Tipo de documento: Article País de afiliação: África do Sul