Your browser doesn't support javascript.
loading
Comparative study of abdominal CT enhancement in overweight and obese patients based on different scanning modes combined with different contrast medium concentrations.
Gao, Kai; Ma, Ze-Peng; Zhang, Tian-Le; Liu, Yi-Wen; Zhao, Yong-Xia.
Afiliação
  • Gao K; Affiliated Hospital of Hebei University/Clinical Medical College, Hebei University, Baoding, China.
  • Ma ZP; Affiliated Hospital of Hebei University/Clinical Medical College, Hebei University, Baoding, China.
  • Zhang TL; Hebei Key Laboratory of Precise Imaging of Inflammation Related Tumors, Baoding, China.
  • Liu YW; Affiliated Hospital of Hebei University/Clinical Medical College, Hebei University, Baoding, China.
  • Zhao YX; Hebei Key Laboratory of Precise Imaging of Inflammation Related Tumors, Baoding, China.
J Xray Sci Technol ; 32(3): 569-581, 2024.
Article em En | MEDLINE | ID: mdl-38217636
ABSTRACT

PURPOSE:

To compare image quality, iodine intake, and radiation dose in overweight and obese patients undergoing abdominal computed tomography (CT) enhancement using different scanning modes and contrast medium.

METHODS:

Ninety overweight and obese patients (25 kg/m2≤body mass index (BMI)< 30 kg/m2 and BMI≥30 kg/m2) who underwent abdominal CT-enhanced examinations were randomized into three groups (A, B, and C) of 30 each and scanned using gemstone spectral imaging (GSI) +320 mgI/ml, 100 kVp + 370 mgI/ml, and 120 kVp + 370 mgI/ml, respectively. Reconstruct monochromatic energy images of group A at 50-70 keV (5 keV interval). The iodine intake and radiation dose of each group were recorded and calculated. The CT values, contrast-to-noise ratios (CNRs), and subjective scores of each subgroup image in group A versus images in groups B and C were by using one-way analysis of variance or Kruskal-Wallis H test, and the optimal keV of group A was selected.

RESULTS:

The dual-phase CT values and CNRs of each part in group A were higher than or similar to those in groups B and C at 50-60 keV, and similar to or lower than those in groups B and C at 65 keV and 70 keV. The subjective scores of the dual-phase images in group A were lower than those of groups B and C at 50 keV and 55 keV, whereas no significant difference was seen at 60-70 keV. Compared to groups B and C, the iodine intake in group A decreased by 12.5% and 13.3%, respectively. The effective doses in groups A and B were 24.7% and 25.8% lower than those in group C, respectively.

CONCLUSION:

GSI +320 mgI/ml for abdominal CT-enhanced in overweight patients satisfies image quality while reducing iodine intake and radiation dose, and the optimal keV was 60 keV.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Radiografia Abdominal / Tomografia Computadorizada por Raios X / Meios de Contraste / Sobrepeso / Obesidade Tipo de estudo: Clinical_trials Limite: Adult / Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Revista: J Xray Sci Technol Assunto da revista: RADIOLOGIA Ano de publicação: 2024 Tipo de documento: Article País de afiliação: China

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Radiografia Abdominal / Tomografia Computadorizada por Raios X / Meios de Contraste / Sobrepeso / Obesidade Tipo de estudo: Clinical_trials Limite: Adult / Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Revista: J Xray Sci Technol Assunto da revista: RADIOLOGIA Ano de publicação: 2024 Tipo de documento: Article País de afiliação: China