Your browser doesn't support javascript.
loading
Automatic detection of myocardial ischaemia using generalisable spatio-temporal hierarchical Bayesian modelling of DCE-MRI.
Yang, Yalei; Husmeier, Dirk; Gao, Hao; Berry, Colin; Carrick, David; Radjenovic, Aleksandra.
Afiliação
  • Yang Y; School of Mathematics & Statistics, University of Glasgow, University Place, Glasgow, G12 8QQ, United Kingdom; Key Laboratory of Carcinogenesis and Translational Research (Ministry of Education/Beijing), Key Laboratory for Research and Evaluation of Radiopharmaceuticals (National Medical Product
  • Husmeier D; School of Mathematics & Statistics, University of Glasgow, University Place, Glasgow, G12 8QQ, United Kingdom. Electronic address: dirk.husmeier@glasgow.ac.uk.
  • Gao H; School of Mathematics & Statistics, University of Glasgow, University Place, Glasgow, G12 8QQ, United Kingdom.
  • Berry C; School of Cardiovascular & Metabolic Health, University of Glasgow, BHF Glasgow Cardiovascular Research Centre (GCRC), 126 University Place, Glasgow, G12 8TA, United Kingdom.
  • Carrick D; University Hospital Hairmyres, 218 Eaglesham Rd, East Kilbride, Glasgow G75 8RG, United Kingdom.
  • Radjenovic A; School of Cardiovascular & Metabolic Health, University of Glasgow, BHF Glasgow Cardiovascular Research Centre (GCRC), 126 University Place, Glasgow, G12 8TA, United Kingdom. Electronic address: aleksandra.radjenovic@glasgow.ac.uk.
Comput Med Imaging Graph ; 113: 102333, 2024 04.
Article em En | MEDLINE | ID: mdl-38281420
ABSTRACT
Dynamic Contrast Enhanced Magnetic Resonance Imaging (DCE-MRI) can be used as a non-invasive method for the assessment of myocardial perfusion. The acquired images can be utilised to analyse the spatial extent and severity of myocardial ischaemia (regions with impaired microvascular blood flow). In the present paper, we propose a novel generalisable spatio-temporal hierarchical Bayesian model (GST-HBM) to automate the detection of ischaemic lesions and improve the in silico prediction accuracy by systematically integrating spatio-temporal context information. We present a computational inference procedure with an adequate trade-off between accuracy and computational efficiency, whereby model parameters are sampled from the posterior distribution with Gibbs sampling, while lower-level hyperparameters are selected using model selection strategies based on the Watanabe Akaike information criterion (WAIC). We have assessed our method on both synthetic (in silico) data with known gold-standard and 12 sets of clinical first-pass myocardial perfusion DCE-MRI datasets. We have also carried out a comparative performance evaluation with four established alternative

methods:

Gaussian mixture model (GMM), opening and closing operations based on Gaussian mixture model (GMMC&Omax), Markov random field constrained Gaussian mixture model (GMM-MRF) and model-based hierarchical Bayesian model (M-HBM). Our results show that the proposed GST-HBM method achieves much higher in silico prediction accuracy than the established alternative methods. Furthermore, this method appears to provide a more robust delineation of ischaemic lesions in datasets affected by spatially variant noise.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Doença da Artéria Coronariana / Imageamento por Ressonância Magnética Tipo de estudo: Diagnostic_studies / Prognostic_studies Limite: Humans Idioma: En Revista: Comput Med Imaging Graph Assunto da revista: DIAGNOSTICO POR IMAGEM Ano de publicação: 2024 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Doença da Artéria Coronariana / Imageamento por Ressonância Magnética Tipo de estudo: Diagnostic_studies / Prognostic_studies Limite: Humans Idioma: En Revista: Comput Med Imaging Graph Assunto da revista: DIAGNOSTICO POR IMAGEM Ano de publicação: 2024 Tipo de documento: Article