Your browser doesn't support javascript.
loading
A comparative study of hepatic steatosis using two different qualitative ultrasound techniques measured based on magnetic resonance imaging-derived proton density fat fraction.
Ogawa, Sadanobu; Kumada, Takashi; Gotoh, Tatsuya; Niwa, Fumihiko; Toyoda, Hidenori; Tanaka, Junko; Shimizu, Masahito.
Afiliação
  • Ogawa S; Department of Imaging Diagnosis, Ogaki Municipal Hospital, Ogaki, Gifu, Japan.
  • Kumada T; Department of Nursing, Faculty of Nursing, Gifu Kyoritsu University, Ogaki, Gifu, Japan.
  • Gotoh T; Department of Imaging Diagnosis, Ogaki Municipal Hospital, Ogaki, Gifu, Japan.
  • Niwa F; Department of Imaging Diagnosis, Ogaki Municipal Hospital, Ogaki, Gifu, Japan.
  • Toyoda H; Department of Gastroenterology and Hepatology, Ogaki Municipal Hospital, Ogaki, Gifu, Japan.
  • Tanaka J; Department of Epidemiology, Infectious Disease Control, and Prevention, Hiroshima University Institute of Biomedical and Health Sciences, Hiroshima, Japan.
  • Shimizu M; Department of Gastroenterology/Internal Medicine, Graduate School of Medicine, Gifu University, Gifu, Japan.
Hepatol Res ; 54(7): 638-654, 2024 Jul.
Article em En | MEDLINE | ID: mdl-38294946
ABSTRACT

AIM:

This study aimed to evaluate the diagnostic performance of attenuation measurement (ATT; dual-frequency method) and improved algorithm of ATT (iATT; reference method) for the assessment of hepatic steatosis using magnetic resonance imaging (MRI)-derived proton density fat fraction (PDFF) as the reference standard.

METHODS:

We prospectively analyzed 427 patients with chronic liver disease who underwent ATT, iATT, or MRI-derived PDFF. Correlation coefficients were analyzed, and diagnostic values were evaluated by area under the receiver operating characteristic curve (AUROC). The steatosis grade was categorized as S0 (<5.2%), S1 (≥5.2%, <11.3%), S2 (≥11.3%, <17.1%), and S3 (≥17.1%) according to MRI-derived PDFF values.

RESULTS:

The median ATT and iATT values were 0.61 dB/cm/MHz (interquartile range 0.55-0.67 dB/cm/MHz) and 0.66 dB/cm/MHz (interquartile range 0.57-0.77 dB/cm/MHz). ATT and iATT values increased significantly as the steatosis grade increased in the order S0, S1, S2, and S3 (p < 0.001). The correlation coefficients between ATT or iATT values and MRI-derived PDFF values were 0.533 (95% confidence interval [CI] 0.477-0.610) and 0.803 (95% CI 0.766-0.834), with a significant difference between them (p < 0.001). For the detection of hepatic steatosis of ≥S1, ≥S2, and ≥S3, iATT yielded AUROCs of 0.926 (95% CI 0.901-0.951), 0.913 (95% CI 0.885-0.941), and 0.902 (95% CI 0.869-0.935), with significantly higher AUROC values than for ATT (p < 0.001, p < 0.001, p = 0.001).

CONCLUSION:

iATT showed excellent diagnostic performance for hepatic steatosis, and was strongly correlated with MRI-derived PDFF, with AUROCs of ≥0.900.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Qualitative_research Idioma: En Revista: Hepatol Res Ano de publicação: 2024 Tipo de documento: Article País de afiliação: Japão

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Qualitative_research Idioma: En Revista: Hepatol Res Ano de publicação: 2024 Tipo de documento: Article País de afiliação: Japão