Your browser doesn't support javascript.
loading
The safety of ABO minor incompatible platelets transfusions using a rapid infuser.
Jung, Yujung; Luo, Oscar; Sen, Nina; Li, Flora M; Hasan, Rida A; Hess, Aaron S; Hess, John R; Sabath, Daniel E; Tsang, Hamilton C; Pagano, Monica B.
Afiliação
  • Jung Y; Department of Laboratory Medicine and Pathology, University of Washington, Seattle, Washington, USA.
  • Luo O; Bloodworks Northwest, Seattle, Washington, USA.
  • Sen N; American Red Cross Northern California Coastal Region, Oakland, California, USA.
  • Li FM; Department of Laboratory Medicine and Pathology, University of Washington, Seattle, Washington, USA.
  • Hasan RA; Department of Anesthesiology and Pain Medicine, University of Washington, Seattle, Washington, USA.
  • Hess AS; Department of Laboratory Medicine and Pathology, University of Washington, Seattle, Washington, USA.
  • Hess JR; Department of Anesthesiology, University of Wisconsin, Madison, Wisconsin, USA.
  • Sabath DE; Department of Pathology & Laboratory Medicine, University of Wisconsin, Madison, Wisconsin, USA.
  • Tsang HC; Department of Laboratory Medicine and Pathology, University of Washington, Seattle, Washington, USA.
  • Pagano MB; Department of Laboratory Medicine and Pathology, University of Washington, Seattle, Washington, USA.
Transfusion ; 64(3): 449-453, 2024 Mar.
Article em En | MEDLINE | ID: mdl-38299721
ABSTRACT

BACKGROUND:

Administering platelets through a rapid infuser is proven to be safe. However, the clinical significance of infusing ABO-incompatible platelets with red blood cells (RBCs) in a rapid infuser remains unclear. There is a theoretical risk that isoagglutinin in the plasma of a platelet unit can interact with RBCs and induce hemolysis. MATERIALS AND

METHODS:

Seven in vitro studies were performed including five cases (type A RBCs and type O platelets) and two controls (type A RBCs and platelets). Anti-A titers were measured in platelet units. An RBC unit and a platelet unit were mixed in the rapid infuser reservoir and incubated for 30 min. The primary outcome was the presence of hemolysis based on the following parameters free hemoglobin concentration, hemolysis check, direct antiglobulin test (DAT), and direct agglutination.

RESULTS:

The post-mix DAT was positive for IgG in all test samples (5/5), and weakly positive for complement in 3/5. The changes in free Hb in test cases between measured and calculated post-mix spanned -2.2 to +3.4 mg/dL. Post-mix hemolysis check was negative in 3/5 and slightly positive in 2/5 cases, with no significant differences compared to the control case. Anti-A titers ranged from 16 to 512 and were not associated with hemolysis. All samples were negative for direct agglutination.

CONCLUSION:

Our study suggested that mixing ABO-incompatible platelets with RBCs in a rapid infuser does not induce in vitro hemolysis. These findings support the use of rapid infusers regardless of platelet compatibility in support of hemostatic resuscitation.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Sistema ABO de Grupos Sanguíneos / Hemólise Limite: Humans Idioma: En Revista: Transfusion Ano de publicação: 2024 Tipo de documento: Article País de afiliação: Estados Unidos