Your browser doesn't support javascript.
loading
Electrochemical HPLC Determination of Piperazine Antihistamine Drugs Employing a Spark-Generated Nickel Oxide Nanoparticle-Modified Carbon Fiber Microelectrode.
Belbasi, Zeynab; Petr, Jan; Sevcik, Juraj; Jirovsky, David; Hrbac, Jan.
Afiliação
  • Belbasi Z; Faculty of Science, Department of Analytical Chemistry, Palacky University, 17. Iistopadu 12, 771 46 Olomouc, Czech Republic.
  • Petr J; Faculty of Science, Department of Analytical Chemistry, Palacky University, 17. Iistopadu 12, 771 46 Olomouc, Czech Republic.
  • Sevcik J; Faculty of Science, Department of Analytical Chemistry, Palacky University, 17. Iistopadu 12, 771 46 Olomouc, Czech Republic.
  • Jirovsky D; Faculty of Science, Department of Analytical Chemistry, Palacky University, 17. Iistopadu 12, 771 46 Olomouc, Czech Republic.
  • Hrbac J; Faculty of Science, Department of Analytical Chemistry, Palacky University, 17. Iistopadu 12, 771 46 Olomouc, Czech Republic.
ACS Omega ; 9(4): 5038-5045, 2024 Jan 30.
Article em En | MEDLINE | ID: mdl-38313503
ABSTRACT
In this work, we demonstrate a sensitive high-performance liquid chromatography (HPLC) method for the determination of piperazine antihistamine drugs employing innovative electrochemical detection based on a spark-generated nickel oxide nanoparticle-modified carbon fiber microelectrode built into a miniaturized electrochemical detector. The direct carbon fiber-to-nickel plate electrode spark discharge, carried at 0.8 kV DC, with the nickel electrode connected to the negative pole of the high-voltage power supply, provides extremely fast (1 s) in situ tailoring of the carbon fiber microelectrode surface by nickel oxide nanoparticles. It has been found that nickel oxide nanoparticles exhibit an electrocatalytic effect toward the piperazine moiety electrooxidation process, as confirmed by voltammetric experiments, revealing the shift in the peak potential from 1.25 to 1.09 V versus Ag/AgCl. Cetirizine, cyclizine, chlorcyclizine, flunarizine, meclizine, and buclizine were selected as sample piperazine antihistamine drugs, while diclofenac served as an internal standard. The isocratic reversed-phase separation of the above set was achieved within 15 min using an ARION-CN 3 µm column with a binary mobile phase consisting of 50 mM phosphate buffer (pH 3) and methanol (45/55, v/v). The limits of detection (LOD) were within the range of 3.8-120 nM (for cyclizine and buclizine) at E = +1500 mV (vs Ag/AgCl), while the response was linear within the concentration range measured up to 5 µmol L-1. The method was successfully applied to the determination of piperazine antihistamine drugs in spiked plasma samples.

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: ACS Omega Ano de publicação: 2024 Tipo de documento: Article País de afiliação: República Tcheca

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: ACS Omega Ano de publicação: 2024 Tipo de documento: Article País de afiliação: República Tcheca