Your browser doesn't support javascript.
loading
New Ceramic Heads With Titanium Sleeves on Retained Femoral Components: Results of Over 500 Revision Total Hip Arthroplasties.
Roberts, Heather J; Hannon, Charles P; Dilger, Oliver B; Bedard, Nicholas A; Berry, Daniel J; Abdel, Matthew P.
Afiliação
  • Roberts HJ; Department of Orthopedic Surgery, Mayo Clinic, Rochester, Minnesota.
  • Hannon CP; Department of Orthopedic Surgery, Mayo Clinic, Rochester, Minnesota.
  • Dilger OB; Department of Orthopedic Surgery, Mayo Clinic, Rochester, Minnesota.
  • Bedard NA; Department of Orthopedic Surgery, Mayo Clinic, Rochester, Minnesota.
  • Berry DJ; Department of Orthopedic Surgery, Mayo Clinic, Rochester, Minnesota.
  • Abdel MP; Department of Orthopedic Surgery, Mayo Clinic, Rochester, Minnesota.
J Arthroplasty ; 39(9S1): S183-S187, 2024 Sep.
Article em En | MEDLINE | ID: mdl-38336305
ABSTRACT

BACKGROUND:

Ceramic heads are frequently combined with titanium sleeves in revision total hip arthroplasties (THAs), ostensibly to protect the ceramic head from existing damage to the retained trunnion. Although widely adopted, data on the performance and safety of this construct are minimal. The purpose of this study was to describe implant survivorships, radiographic results, and clinical outcomes of patients who underwent revision THA with a ceramic head and titanium sleeve on a retained femoral component.

METHODS:

We identified 516 revision THAs with femoral component retention (328 acetabular-only revisions and 188 bearing surface exchanges) treated with a new ceramic head and titanium sleeve between 2000 and 2020. Mean age at revision was 64 years, 56% were women, and mean body mass index was 30. The indications for revision THA were adverse local tissue reaction (25%), acetabular loosening (24%), dislocation (17%), infection (5%), and other (29%). Kaplan-Meier survivorships were analyzed, radiographs reviewed, and Harris Hip Scores evaluated. Mean follow-up was 4 years (range, 2 to 10).

RESULTS:

There were no reoperations or failures for ceramic head fracture, taper corrosion, or head/sleeve disengagement. The 10-year survivorship free of any re-revision was 85%. Indications for the 57 re-revisions included dislocation (33), infection (13), acetabular component loosening (7), periprosthetic fracture (2), psoas impingement (1), and sciatic nerve irritation (1). The 10-year survivorship free of any reoperation was 82%. There were an additional 14 reoperations. Radiographically, 1.9% had progressive femoral radiolucent lines, and 4.7% had progressive acetabular radiolucent lines. Mean Harris Hip Score was 81 at 2 years.

CONCLUSIONS:

New ceramic heads with titanium sleeves in revision THAs with retained femoral components were durable and reliable with no cases of ceramic head fracture or taper complications at mean 4-year follow-up, including those revised for adverse local tissue reaction. LEVEL OF EVIDENCE IV.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Desenho de Prótese / Reoperação / Titânio / Falha de Prótese / Cerâmica / Artroplastia de Quadril / Prótese de Quadril Tipo de estudo: Prognostic_studies Limite: Adult / Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Revista: J Arthroplasty Assunto da revista: ORTOPEDIA Ano de publicação: 2024 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Desenho de Prótese / Reoperação / Titânio / Falha de Prótese / Cerâmica / Artroplastia de Quadril / Prótese de Quadril Tipo de estudo: Prognostic_studies Limite: Adult / Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Revista: J Arthroplasty Assunto da revista: ORTOPEDIA Ano de publicação: 2024 Tipo de documento: Article