Your browser doesn't support javascript.
loading
Distal Repair After Total Aortic Arch Replacement With Frozen Elephant Trunk in Patients With Chronic Multilevel Thoracic Aortic Disease.
Doonan, Robert-James; Senanayake, Eshan; Claridge, Martin; Juszczak, Maciej; Torella, Francesco; Mascaro, Jorge; Field, Mark; Adam, Donald J.
Afiliação
  • Doonan RJ; Division of Vascular Surgery, McGill University Health Centre, Montreal, Canada; Liverpool University Hospitals, Liverpool, UK.
  • Senanayake E; University Hospitals Birmingham NHS Foundation Trust, Birmingham, UK.
  • Claridge M; University Hospitals Birmingham NHS Foundation Trust, Birmingham, UK.
  • Juszczak M; University Hospitals Birmingham NHS Foundation Trust, Birmingham, UK.
  • Torella F; Liverpool University Hospitals, Liverpool, UK; Liverpool Heart and Chest Hospital, Liverpool, UK.
  • Mascaro J; University Hospitals Birmingham NHS Foundation Trust, Birmingham, UK.
  • Field M; Liverpool Heart and Chest Hospital, Liverpool, UK.
  • Adam DJ; University Hospitals Birmingham NHS Foundation Trust, Birmingham, UK. Electronic address: donald.adam@uhb.nhs.uk.
Eur J Vasc Endovasc Surg ; 68(1): 73-81, 2024 Jul.
Article em En | MEDLINE | ID: mdl-38403183
ABSTRACT

OBJECTIVE:

To examine the management of distal aortic disease after total arch replacement with the frozen elephant trunk (TAR + FET) in patients with chronic thoracic aortic disease.

METHODS:

Two centre retrospective study of consecutive patients treated between January 2010 and December 2019. The primary endpoint was 30 day or in hospital death. The secondary endpoint was midterm survival. Data are presented as median (interquartile range [IQR]). The χ2 or Fisher's exact test was used as appropriate. Estimated survival (standard error) was assessed by calculating the Kaplan-Meier product limit estimator with right censoring of survival data. A p value of < .050 was considered statistically significant. STROBE guidelines were followed.

RESULTS:

A total of 158 patients (72 men; median age 70 years, IQR 64, 75; median distal aortic diameter 58 mm, IQR 46, 68; 127 aneurysmal disease, 31 chronic dissection) underwent TAR + FET. The peri-operative mortality rate was 10.1% (9/107 elective, 7/51 non-elective). Of 74 (46.8%) patients with a primary distal seal, seven (9.5%) died peri-operatively, the distal seal was maintained during follow up in 51, nine underwent late distal repair (two planned, seven unplanned; one open, eight endovascular; one peri-operative death) with a median interval to unplanned repair of 777 days (IQR 462, 1480), and seven with loss of seal had no intervention. Distal seal failed in 2/28 (7%) patients with a distal seal length > 30 mm and device oversizing > 10%, compared with 12/39 (31%) patients who did not meet these criteria (p = .031). In 84 patients without a primary distal seal, nine (10.7%) died peri-operatively, the distal aorta remained below the size threshold for repair during follow up in 12 patients, 44 had distal repair (median aortic diameter 64 mm, IQR 60, 75; eight open, one hybrid, 35 endovascular repairs; no deaths) at a median of 256 days (IQR 135, 740), and 19 did not have distal repair at the end of the follow up period six died before planned repair at a median interval of 115 days (IQR 85, 120); eight were considered unfit; one was assessed as fit but declined; and four patients were awaiting assessment. Median follow up was 46 months (IQR 26, 75) no patients were lost to follow up. Estimated ± standard error five year survival was 61.5 ± 4.1% elective 70.6 ± 4.7%, non-elective 43.2 ± 7.2%.

CONCLUSION:

TAR + FET achieved primary distal seal in 47% of patients, but late failure occurred in 21%. Distal repair was ultimately indicated in 84% of survivors without a primary distal seal and of these 70% underwent repair, almost 10% died before planned repair, and 13% were considered unfit. Earlier distal endovascular repair and better assessment of patient fitness may improve midterm outcomes.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Aorta Torácica / Aneurisma da Aorta Torácica / Implante de Prótese Vascular Limite: Aged / Female / Humans / Male / Middle aged Idioma: En Revista: Eur J Vasc Endovasc Surg Assunto da revista: ANGIOLOGIA Ano de publicação: 2024 Tipo de documento: Article País de afiliação: Reino Unido

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Aorta Torácica / Aneurisma da Aorta Torácica / Implante de Prótese Vascular Limite: Aged / Female / Humans / Male / Middle aged Idioma: En Revista: Eur J Vasc Endovasc Surg Assunto da revista: ANGIOLOGIA Ano de publicação: 2024 Tipo de documento: Article País de afiliação: Reino Unido