Your browser doesn't support javascript.
loading
Differential Cantilever Enhanced Fiber-Optic Photoacoustic Sensor for Diffusion Gas Detection.
Li, Chenxi; Zhang, Yajie; Guo, Min; Qi, Hongchao; Zhao, Xinyu; Chen, Ke.
Afiliação
  • Li C; School of Optoelectronic Engineering and Instrumentation Science, Dalian University of Technology, Dalian, Liaoning 116024, China.
  • Zhang Y; School of Optoelectronic Engineering and Instrumentation Science, Dalian University of Technology, Dalian, Liaoning 116024, China.
  • Guo M; Zhejiang Engineering Research Center of MEMS, Shaoxing University, Shaoxing, Zhejiang 312000, China.
  • Qi H; School of Optoelectronic Engineering and Instrumentation Science, Dalian University of Technology, Dalian, Liaoning 116024, China.
  • Zhao X; School of Optoelectronic Engineering and Instrumentation Science, Dalian University of Technology, Dalian, Liaoning 116024, China.
  • Chen K; School of Optoelectronic Engineering and Instrumentation Science, Dalian University of Technology, Dalian, Liaoning 116024, China.
Anal Chem ; 96(11): 4562-4569, 2024 Mar 19.
Article em En | MEDLINE | ID: mdl-38451124
ABSTRACT
Aiming at the problem of the fiber-optic photoacoustic (PA) sensor being easily disturbed by external vibration and noise, a differential cantilever enhanced fiber-optic PA sensor is proposed for diffusion gas detection. The sensor comprises two PA tubes with the same structure and a pair of differential interferometric cantilevers. The two PA tubes are symmetrically distributed. The laser is incident on the PA tube as the signal channel to excite the PA pressure wave. Another tube without incident laser is used as the reference channel to suppress external disturbance. The external interference signals and PA signals superimposed with disturbance are detected by the differential cantilevers from the two channels. The signals are simultaneously restored by a single white-light interferometry demodulator, which multiplexed the spectral frequency domain of the superimposed interference spectrum. The experimental results show that the suppression effect of the differential cantilever enhanced PA sensor on ambient noise is improved by 80%, compared to the traditional single-cantilever sensor. The external cofrequency disturbance is suppressed by 20.9 dB. The minimum detection limit to acetylene (C2H2) downs to about 60 ppb with an integration time of 100 s. The sensor has excellent antivibration and electromagnetic interference ability.

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: Anal Chem Ano de publicação: 2024 Tipo de documento: Article País de afiliação: China

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: Anal Chem Ano de publicação: 2024 Tipo de documento: Article País de afiliação: China