Your browser doesn't support javascript.
loading
Dynamic performance of rotor-side nonlinear control technique for doubly-fed multi-rotor wind energy based on improved super-twisting algorithms under variable wind speed.
Benbouhenni, Habib; Yessef, Mourad; Colak, Ilhami; Bizon, Nicu; Kotb, Hossam; AboRas, Kareem M; ELrashidi, Ali.
Afiliação
  • Benbouhenni H; Department of Electrical & Electronics Engineering, Faculty of Engineering and Architecture, Nisantasi University, Istanbul, 34481742, Turkey.
  • Yessef M; LIMAS Laboratory, Faculty of Sciences Dhar El Mahraz, SMBA University, 30002, Fez, Morocco. mourad.yessef@usmba.ac.ma.
  • Colak I; Department of Electrical & Electronics Engineering, Faculty of Engineering and Architecture, Nisantasi University, Istanbul, 34481742, Turkey.
  • Bizon N; Pitești University Center, The National University of Science and Technology POLITEHNICA Bucharest, 110040, Pitesti, Romania.
  • Kotb H; ICSI Energy, National Research and Development Institute for Cryogenic and Isotopic Technologies, 240050, RamnicuValcea, Romania.
  • AboRas KM; Department of Electrical Power and Machines, Alexandria University, Alexandria, 21544, Egypt.
  • ELrashidi A; Department of Electrical Power and Machines, Alexandria University, Alexandria, 21544, Egypt.
Sci Rep ; 14(1): 5664, 2024 Mar 07.
Article em En | MEDLINE | ID: mdl-38453951
ABSTRACT
The paper proposes a nonlinear controller called dual super-twisting sliding mode command (DSTSMC) for controlling and regulating the rotor side converter (RSC) of multi-rotor wind power systems that use doubly-fed induction generators. It was proposed that this controller be developed as an alternative to the direct power control (DPC), which makes use of a pulse width modulation (PWM) strategy to regulate the RSC's functioning. Overcoming the power/current quality issue with the proposed technique (DPC-DSTSMC-PWM) is characterized by great robustness and excellent performance. The designed strategy was contrasted with the standard method of control and other methods already in use. So, the unique proposed control strategy's robustness, performance, efficiency, and efficacy in enhancing system characteristics were tested and validated in Matlab/Simulink. In both tests, the proposed method resulted in significant improvements, reducing active power ripples by 83.33%, 57.14%, and 48.57% in the proposed tests. When compared with the traditional regulation method, the reduction rates of reactive power ripples are 64.06%, 52.47%, and 68.7% in the tests. However, in contrast to the conventional method, the proposed tests showed a decrease of between 72.46%, 50%, and 76.22% in the value of total harmonic distortion (THD) of the provided currents. These ratios show how effective the proposed plan is in ameliorating and enhancing aspects of the energy system.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: Sci Rep Ano de publicação: 2024 Tipo de documento: Article País de afiliação: Turquia

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: Sci Rep Ano de publicação: 2024 Tipo de documento: Article País de afiliação: Turquia